Description
SDCS-PIN-48-SD The 250 ohm resistor converts input current to a voltage with respect to common. The input R-C
filters high-frequency noise, while the opamp buffers the signal to the analog/digital converter. All
eight +24 VDC Out terminals are common to each other. SDCS-PIN-48-SD The chassis ground goes to the I/O
Terminal Block ground terminal.
brand | Product Name | Product model | Order No |
ABB | modular | SDCS-PIN-48-SD | 3BSE004939R1012 |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1806092-3929 |
SDCS-PIN-48-SD The input signals share a single signal common return. For good noise immunity, establish system
signal commons, power supply reference points, and grounds close to such single-ended points.
Signal common (as defined by most Standards) for the input module is the negative side of the 24
volt supply. The module’s chassis ground goes to the I/O Terminal Block ground terminal. To
improve noise immunity, connect this to the enclosure chassis with a short length of wire.
Two wire loop powered transmitters (type 2) should have isolated or ungrounded sensor inputs.
Loop powered devices should use the same power supply as the input module. If a different supply
must be used, connect the signal common to the module common. Also, SDCS-PIN-48-SD ground only one point on
the signal common, preferably at the input module. If the power supply is not grounded, the entire
analog network is at a floating potential (except for the cable shields). Thus this circuit can be
isolated if it has a separate isolated supply.
SDCS-PIN-48-SD If shielded wire is used to reduce noise pickup, the shield drain wires should have a separate path to
ground from any loop power supply ground to avoid inducing noise due to drain current.
Three wire transmitters require a third wire to provide power. The shield may be used as the
power supply return. If the system is isolated, a third wire (triad cable) should be used instead of
the shield for the power, and the shields grounded.
A separate, remote power supply can also be used. A floating supply should be used for best
results. Grounding both supplies creates a ground loop. The circuit may still work despite this,
however achieving good results requires very good voltage compliance of the transmitter.
Isolated 4 wire transmitters can avoid ground loop problems with remotely powered sensors.
If the module is installed on an I/O Terminal Block with Barrier Terminals or an I/O Terminal
Block with Wire to Board Connectors, additional wiring terminals are needed. For an I/O Terminal
Block with Barrier Terminals, an Auxiliary SDCS-PIN-48-SD Terminal Block can be used. For the I/O Terminal
Block with Wire to Board Connectors, external connection points are usually preferred, although an
Auxiliary Terminal Block can also be used.
Auxiliary Terminal Blocks have all terminals connected together internally. The Auxiliary
Terminal Block with box terminals has 13 terminals, each of which accommodates one AWG #14
(avg 2.1mm2 cross section) to AWG #22 (avg 0.36mm2 cross section) wire, or two wires up to
AWG #18 (avg. 0.86mm2 cross section). The Auxiliary Terminal Block with barrier terminals has
nine terminals, each of which can accommodate one or two wires up to AWG #14 (avg 2.1mm2
cross section)
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen