ABB UAD149 After sales service is provided for the control card of the power supply device

Numer modelu: UAD149

Manufacturer: ABB
Quantity:ten
Serial ports: 2
Network ports: 9
Port isolation: 120 VDC
Weight :3Kg
Shipping Weight :5 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number UAD149
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

Supposing the need to change from 0.8 to 0.93 the power factor of a threephase installation (Ur
= 400 V) which absorbs an average power of 300 kW.
From Table 2, at the intersection of the column corresponding to the final
power factor (0.93), and the row corresponding to the starting power factor
(0.8), the value of Kc
(0.355) can be read. The reactive power Qc
which must
be generated locally shall be:
Qc
= Kc
. P = 0.355 . 300 = 106.5 Kvar
Due to the effect of power factor correction, the current absorbed decreases
from 540 A to 460 A (a reduction of approximately 15%).
Characteristics of power factor correction capacitor banks
The most economical means of increasing the power factor, especially for an
installation which already exists, is installing capacitors.
Capacitors have the following advantages:
– low cost compared with synchronous compensators and electronic power
converters;
– ease of installation and maintenance;
– reduced losses (less than 0.5 W/kvar in low voltage);
– the possibility of covering a wide range of powers and different load profiles,
simply supplying in parallel different combinations of components, each with
a relatively small power.
The disadvantages are sensitivity to overvoltages and to the presence of nonlinear loads.
The Standards applicable to power factor correction capacitors are as
follows:
– IEC 60831-1 “Shunt power capacitors of the self-healing type for a.c.
systems having a rated voltage up to and including 1000 V – Part 1: General
– Performance, testing and rating – Safety requirements – Guide for installation
and operation”;
– IEC 60931-1 “Shunt power capacitors of the non-self-healing type for a.c.
systems having a rated voltage up to and including 1000 V – Part 1: GeneralPerformance, testing and rating – Safety requirements – Guide for installation
and operation”.