Description
If any individual phase current exceeds the pickup level for the XU D194 specified trip time a trip will occur if the feature is enabled.
The element operates in both online and offline conditions. This element can be used as a backup feature to other protec
tion elements. In situations where generators are connected in parallel this element would be set above the maximum cur
rent contribution from the generator on which the protection is installed. With this setting, the element would provide proper
selective tripping. The basic operating time of the element with no time delay is 50 ms at 50/60 Hz.
brand | Product Name | Product model | Order No |
ABB | modular | XU D194 | 3BHE018137R0001 |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1806092-3929 |
The XU D194 overvoltage elements may be used for protection of the generator and/or its auxiliary equipment during prolonged
overvoltage conditions. They are always active (when the generator is offline or online). The alarm element is definite time
and the trip element can be either definite time or an inverse time curve. When the average of the measured phase-phase
voltages rises above the pickup level x the generator rated phase-phase voltage, the element will begin to time out. If the
time expires, a trip or alarm will occur. The reset rate is a linear reset time from the threshold of trip. The pickup levels are
insensitive to frequency over the range of 5 to 90 Hz.
The Volts/Hertz elements may be used generator and unit transformer protection. They are active as soon as the magni
tude and frequency of Vab is measurable. The XU D194 alarm element is definite time; the trip element can be definite time or a
curve. Once the V/Hz measurement Vab exceeds the pickup level for the specified time, a trip or alarm will occur. The reset
rate is a linear reset time from the threshold of trip and should be set to match cooling characteristics of the protected
equipment. The measurement of V/Hz will be accurate through a frequency range of 5 to 90 Hz. Settings less than 1.00
only apply for special generators such as short circuit testing machines.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen