XVC768AE123 3BHB007211R0123 ABB control circuit board industrial control accessories

Digital model: XVC768AE123 3BHB007211R0123
Manufacturer: ABB
Weight: 1Kg
Shipping weight: 2Kg
Quantity: 2
Warranty:1 year
Imported: Yes
Available for sale: nationwide
Shipping term:DHL / FEDEX/ EMS /UPS/TNT/EMS

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Operation of earthing switch from opening to closing
(1) XVC768AE123 confirms that the circuit breaker handcart is at the test position, the grounding switch is at the opening position, and the high voltage is not charged.
(2) Close the secondary control power supply, the grounding switch locking electromagnet makes a closing sound, and close the cable chamber door.
(3) Press down the sliding plate of the operating hole of the grounding switch, and insert the operating handle of the grounding switch into the operating hole in the vertical direction to cover the hexagonal operating shaft.
(4) The left hand helps the “L” shaped shaft end of the operating handle to grasp the shaft center; Hold the end of the operating handle with your right hand and turn it 180 ° clockwise or vertically.
(5) After the operating handle is in place, pull out the operating handle horizontally. At this time, the slide of the operating hole can generally spring up automatically. If the slide cannot spring up, lift the slide manually.
(6) XVC768AE123 white plastic position indicator of grounding switch operating hole indicates red “1”; The position display of the grounding switch on the upper door panel shows a red “1”, indicating that the grounding switch is closed.


4.4.2 Operation of earthing switch from closing to opening
Operate in reverse order according to 4.4.1.
4.5 Operation of closing and opening cabinet door
4.5.1 Operation of closing and opening the upper cabinet door
(1) Close the upper cabinet door: insert the cabinet door key horizontally into the key hole in the middle of the upper cabinet door, and turn it about 120 ° counterclockwise to the left to close the cabinet door inwards. At this time, the cabinet door key should also be included in the key hole. Continue to turn the key about 120 ° clockwise to the right, fasten the cabinet door, and then pull out the key.
(2) Opening of the upper cabinet door: insert the cabinet door key horizontally into the key hole in the middle of the upper cabinet door, turn it about 120 ° counterclockwise to the left, and then open the cabinet door outward. At this time, the cabinet door key should also be included in the key hole. Continue to turn the key about 120 ° clockwise to the right, and then pull out the key.
Note: If the cabinet door key cannot be inserted into the key hole in the middle of the upper cabinet door of XVC768AE123, the upper cabinet door cannot be closed and opened. Solution: When the upper cabinet door is already open, pull the long interlocking rod inside the upper cabinet door down to the right place to insert the key; When the upper cabinet door is already closed, use pointed nose pliers to push the slots on both sides of the key hole to the horizontal position to insert the key.
4.5.2 Operation of closing and opening the middle cabinet door
▲ Before closing and opening the middle cabinet door, please confirm that the circuit breaker handcart and PT handcart are at the test position.
▲ When the circuit breaker handcart and PT handcart are in the working position, the middle cabinet door will be forcibly locked, and it is strictly prohibited to open the cabinet door. In case of emergency, a 5 # Allen wrench can be used to unscrew the M8 yellow ball head bolt in the middle of the cabinet door and unlock it to open the cabinet door.
(1) Closing of middle cabinet door:
Lift the operating handle of the cabinet door outward with the right hand, press the palm of the left hand against the lower position beside the operating handle, firmly close it forward, and then buckle the operating handle inward.
be careful:
① . If only the lower side of the cabinet door is not fully closed, the operating handle will not be able to be fastened in. At this time, you can pat the lower side of the middle cabinet door with your palm.
② If the cabinet door cannot be fully closed, the operating handle will not be fastened inward. At this time, check whether the upper, middle and lower studs of the cabinet body touch the upper, middle and lower positioning holes in the middle cabinet door. If they do, adjust the corresponding studs.
③ If the cabinet door cannot be fully closed, the operating handle will not be able to be fastened inward. At this time, the long interlocking rod inside the middle cabinet door should also be checked for deformation. If it is deformed, it should be removed and readjusted.
④ If the cabinet door cannot be fully closed, the operating handle will not be able to be fastened inward. At this time, check whether the “L” shaped handcart unlocking piece in the middle cabinet door cannot be fully inserted into the black interlocking block in the middle of the handcart. If not, adjust it.
(2) Opening of middle cabinet door: lift the cabinet door handle outward with the right hand and pull it outward to open the cabinet door.
Note: If it is difficult to open the cabinet door, it is generally caused by the sagging deformation of the cabinet door. At this time, a large slotted screwdriver or crowbar can be used to pry outward from the gap on the upper edge of the middle cabinet door to open the cabinet door, and then use a hammer to knock down the upper, middle and lower three studs of the cabinet evenly.
4.5.3 Operation of closing and opening the lower cabinet door
▲ Before closing and opening the lower cabinet door, for the high-voltage cabinet with grounding switch, please confirm that the grounding switch is in the closing position.
▲ Before the operation of closing and opening the lower cabinet door, for PT cabinet or isolation cabinet, please confirm that the high voltage is not charged, the secondary control power supply is energized, and the door locking electromagnet DTN of the lower cabinet door is energized.
▲ If the above two requirements are not met, the lower cabinet door cannot be closed and opened. In case of emergency, a 5 # Allen wrench can be used to unscrew the M8 yellow ball head bolt in the middle of the cabinet door and unlock it to open the cabinet door.
(1) Closing of lower cabinet door:
Lift the door handle outward with the right hand, press the palm of the left hand against the lower position beside the handle, firmly close it forward, and then buckle the handle inward. be careful:
① . If only the lower side of the cabinet door is not fully closed, the operating handle will not be able to be fastened in. At this time, you can pat the lower side of the middle cabinet door with your palm.
② If the cabinet door cannot be fully closed, the operating handle will not be fastened inward. At this time, check whether the upper, middle and lower studs of the cabinet body touch the upper, middle and lower positioning holes in the middle cabinet door. If they do, adjust the corresponding studs.
③ If the cabinet door cannot be fully closed, the operating handle will not be able to be fastened inward. At this time, the long interlocking rod inside the middle cabinet door should also be checked for deformation. If it is deformed, it should be removed and readjusted.
(2) Opening of lower cabinet door:
① For high-voltage cabinet with grounding switch, after confirming that the grounding switch is in the closing position, lift the operating handle of the cabinet door outward with the right hand and pull it outward to open the cabinet door.
② For PT cabinet or isolation cabinet, confirm that the high voltage is not electrified and the secondary control power supply is electrified. After the door locking electromagnet DTN of the lower cabinet door is electrified, press down the slide of the operation hole between the middle door and the lower door with the left hand, and pull the operation handle of the cabinet door outward with the right hand to open the cabinet door.
Note: If it is difficult to open the cabinet door, it is generally caused by the sagging deformation of the cabinet door. At this time, a large slotted screwdriver or crowbar can be used to pry outward from the gap on the upper edge of the middle cabinet door to open the cabinet door. Then use a hammer to knock down the upper, middle and lower studs of the cabinet body evenly, so that the opening of the lower cabinet door is easier.

details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.