BENTLY 125840-01 (3500/15 small card) vibration module parameter details

Product name:BENTLY 125840-01 (3500/15 small card) vibration module parameter details

Product model:125840-01

Quantity: inventory

Warranty: We provide warranty service for 125840-01

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

125840-01 Take note of the following items when daisy chaining Rack Interface I/O Modules:

  • Use the HOST port to connect to the host computer or to the rack in the daisy

chain that is closer to the host computer.

  • Use the RACK RS-422 port to connect to the rack that is farther from the host

computer.

  • Use the following cables for the connection between the racks in the daisy

chain:

-125840-01 For lengths of 150 meters (500 ft) or less, use cable

  • 130122-XXXX-XX (PVC Insulation) or cable 131107-XXXX-XX (Teflon®

Insulation).

– For lengths greater than 150 meters (500 ft), use one cable

– 130122-XXXX (PVC Insulation) or cable 131107-XXXX-XX (Teflon®

Insulation) along 125840-01 with as many RS-422 extension cables

– 130121-XX-XX (150 meters (500 ft) standard length) to create a

cable up to 1220 meters (4000 ft) in length.

Refer to Section 7 for the specific options for the cables listed above

 

brand Product Name Product model Order No
BENTLY modular 125840-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1806092-3929

 

125840-01 To remove a terminal block from its base, loosen the screws attaching the

terminal block to the base and then grip the block firmly and pull. Do not pull the

block out by its wires because this could loosen or damage the wires or

connector.

Typical I/O Module

Refer to the 3500 Field Wiring Diagram Package for the recommended wiring.

Also, do not remove more than 6 mm (0.25 inches) of insulation from the wires.

The Data Manager I/O Module must be installed

behind the Power Supplies between the Power Input

Modules and the Rack Interface I/O Module (in a Rack

Mount or Panel Mount rack) or above the Power

Supplies between the Power Input Modules and the

Rack Interface I/O Module (in a Bulkhead rack). The

125840-01 function of the Data Manager I/O module is to connect

the 3500 rack to TDIX or DDIX Communication

Processors. Each port can connect up to 24 channels,

from the 3500 rack to the Communication Processor.

Refer to the table on page 12 for the different options

that are available.

1) Used to transfer the static information from Port 1 of

this 3500 rack to the static connector on the

Communication Processor.

2) Used to transfer the 125840-01 dynamic information from Port

1 of this 3500 rack to the dynamic connector on

the Communication Processor.

3) Used to transfer the information from Port 2 of this

3500 rack to the static connector on the

Communication Processor.

4) Used to transfer the dynamic information from Port

2 of this 3500 rack to the dynamic connector on

the Communication Processor

This section shows how to verify that the Rack Interface Module and the I/O modules

are operating correctly. When performed properly, this module may be installed into

or removed from the rack while power is applied to the rack. Refer to the Rack

Installation and Maintenance Manual (part number 129766-01) for the proper

procedure.

5.1 RIM Host Port Test Utility

Use the RIM Host Port Test Utility to verify that the HOST ports on the Rack

Interface Module and the Rack Interface I/O Module are operating properly.

Before running the RIM Host Port Test Utility, connect Cable 130118-XXXX-XX

(Host to 3500 Rack RS-232 Interface Cable) between the Configuration Port

connector on the front of the Rack Interface Module or to the HOST connector on

the Rack Interface I/O Module and the computer that has the utility installed.

Refer to the 3500 Monitoring System Rack Configuration and Utilities Guide and

the Rack Configuration Software for the details of this utility

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen