3500/22M 138607-01 BENTLY Card Module Power System

Product name:3500/22M 138607-01 BENTLY Card Module Power System

Product model:138607-01

Quantity: inventory

Warranty: We provide warranty service for 138607-01

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

138607-01 Can be used when a Keyphasor is not available. If this is marked then

the only data that will be available is Direct and Gap. This field will

automatically be marked for 138607-01 channel pairs which do not require a

Keyphasor transducer (for example Thrust Position and Differential

Expansion).

Primary

138607-01 The Keyphasor channel selected that is normally used for measurement.

When this Keyphasor transducer is marked invalid, the backup

Keyphasor transducer will provide the shaft reference information.

Backup

The Keyphasor channel selected that will be used if the primary

Keyphasor fails. If you do not have a backup Keyphasor, select the same

Keyphasor channel as the primary Keyphasor.

 

brand Product Name Product model Order No
BENTLY modular 138607-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1806092-3929

 

138607-01 This section discusses the Configuration Considerations and the Rack

Configuration Software screens associated with the Radial Vibration Channel.

3.1.2.1 Radial Vibration Channel Configuration Considerations

Consider the following items before configuring a Radial Vibration Channel:

– Internal Barrier I/O Modules and External barriers are not currently

supported with 7200 11 mm or 14 mm, 138607-01 or 3000 Proximitors, or the 3300 16

mm HTPS.

– When “No Keyphasor” is selected, the 1X Amplitude (Ampl) and Phase Lag, 2X

Amplitude (Ampl) and Phase Lag, 138607-01 Not 1X Amplitude (Ampl), and Smax

Amplitude (Ampl) can not be selected.

– If a Keyphasor channel is selected, a Keyphasor Module must be installed in

the rack.

– The full scale options allowed for each proportional value is dependent upon

the transducer type.

– If a Non-Standard transducer is selected, the setpoint OK limits are set to ±1

volt from the Upper and Lower OK limits that are selected.

– There are two selections for 3000 Series transducers:

3000(-24V) Proximitor

Select this option when connecting a 3000 Series proximitor directly to

a 3500 monitor. 138607-01 A default scale factor of 285 mV/mil will be selected.

This may be adjusted ±15 %. Note that the buffered transducers on

the front of the monitors and to the Data Manager are not

compensated and should be interpreted at 285 mV/mil.

3000(-18V) Proximitor

Select this option when connecting a 3000 Series proximitor directly to

a 3500 monitor, but supplying proximitor power from an external 18

volt source. A default scale factor of 200 mV/mil will be selected. This

may be adjusted ±15 %. Note that the buffered transducers on the

front of the monitors and to the Data Manager are not compensated

and should be interpreted at 200 mV/mil.

– Setpoints may only be set on proportional values which are enabled.

Monitors must be configured in channel pairs (for example, Channels 1 and 2

may be configured as Radial Vibration and Channels 3 and 4 may be

configured as Thrust Position).

– When a full-scale range is modified, the setpoints associated with this

proportional value should be readjusted.

– It is best to set the Scale Factor value and the Trip Multiply value before the

Zero Position value.

– 3000 (-18V), 3000 (-24V), and 3300 RAM Proximitors have limited linear

ranges. Therefore, you should use caution when selecting the Full-scale

range of the Direct, 1X Amplitude (Ampl), 2X Amplitude (Ampl), Not 1X

Amplitude (Ampl) and Smax Amplitude (Ampl) PPLs. Full-scale value x Trip

Multiply should not exceed the linear range of the transducer.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen