Description
176449-08 Once an alarm is active it will remain active even after the proportional
value drops below the configured setpoint level. The channel will remain
in alarm until it is reset using one of 176449-08 the following methods:
– the reset switch on the front of the Rack Interface Module
– the contact on the Rack Interface I/O Module
– the Reset button in the Operator Display Software
– the reset command through the 176449-08 Communication Gateway Module
– the reset command through the Display Interface Module
– the reset command in the Rack Configuration Software
brand | Product Name | Product model | Order No |
BENTLY | modular | 176449-08 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1806092-3929 |
176449-08 Nonlatching
When an alarm is active it will go inactive as soon as the proportional
value drops below the configured setpoint level.
Alert should be the first level alarm that occurs when the transducer signal
level exceeds the selected value. Danger should be the second level alarm
that occurs when the transducer signal level exceeds the selected value.
The Alert and Danger values are set on the Setpoint screen.
Select the MTL 796(-) Zener External option, or Galvanic Isolators if external safety
barriers are connected between the monitor and the transducer. If using an
Internal Barrier I/O Module, select the internal option. These devices are used to
restrict the amount of energy that can flow into a hazardous area.
3.1.3 176449-08 Thrust Position Channel Options
This section discusses the Configuration Considerations and the Rack
Configuration Software screens associated with the Thrust Position Channel.
3.1.3.1 Thrust Position Channel Configuration Considerations
Consider the following items before 176449-08 configuring a Thrust Position Channel:
– Internal Barrier I/O Modules are not currently supported with 7200 11
mm or 14 mm, or 3000 Proximitors, or the 3300 16 mm HTPS.
The “No Keyphasor” option is automatically selected for this channel
type. No Keyphasors are required.
– The Thrust Direct full-scale range is dependent upon the transducer type.
– The Zero Position voltage range is dependent upon the direct full-scale
range and the upscale direction.
– Monitors must be configured in channel pairs (for example, Channels 1
and 2 may be configured as Thrust Position and Channels 3 and 4 may
be configured as Radial Vibration).
– When a full-scale range is modified, the setpoints associated with this
proportional value should be readjusted.
– If a Non-Standard transducer is selected, the setpoint OK limits are set to
±1 volt from the Upper and Lower OK limits that are selected.
– There are two selections for 3000 Series transducers:
3000(-24V) Proximitor
Select this option when connecting a 3000 Series proximitor directly to
a 3500 monitor. A default scale factor of 285 mV/mil will be selected.
This may be adjusted ±15 %. Note that the buffered transducers on
the front of the monitors and to the Data Manager are not
compensated and should be interpreted at 285 mV/mil.
3000(-18V) Proximitor
Select this option when connecting a 3000 Series proximitor directly to
a 3500 monitor, but supplying proximitor power from an external 18
volt source. A default scale factor of 200 mV/mil will be selected. This
may be adjusted ±15 %. Note that the buffered transducers on the
front of the monitors and to the Data Manager are not compensated
and should be interpreted at 200 mV/mil.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen