Description

1900/65A-01-01-02-00-00 The time which a proportional value must remain at or above an over

alarm level or below an under alarm level before an alarm is declared as

active.

Alert

First level alarm that occurs 1900/65A-01-01-02-00-00 when the transducer signal level exceeds the

selected Alert/Alarm 1 setpoint. This setpoint can be set on the Setpoint

screen. The Alert time delay is always set at one second intervals (from 1

to 60) for all available proportional values.

 

brand Product Name Product model Order No
BENTLY modular 1900/65A-00-00-02-00-00 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1806092-3929

 

1900/65A-01-01-02-00-00 Second level alarm that occurs when the transducer signal level exceeds

the selected Danger/Alarm 2 setpoint. This setpoint can be set on the

Setpoint screen.

100 ms option

The 100 ms (typical) option applies to the Danger time delay only and

has the following results:

If the 100 ms option is off ( ):

– The Danger time delay can be set 1900/65A-01-01-02-00-00 at one second intervals (from 1

through 60).

– The Danger time delay can be set for all available proportional values.

If the 100 ms option is on ( ):

– The Danger time delay is set to 100 ms.

– The Danger time delay can only be set for the primary proportional

value.

Zero Position (Direct)

Represents the transducer DC voltage corresponding to the zero indication on the

1900/65A-01-01-02-00-00 channel’s meter scale for the direct proportional value. The amount of

adjustment allowed is dependent upon the Direct Full Scale Range and the

transducer OK limits. For maximum amount of zero adjustment, gap the

transducer as close as possible to the ideal zero position voltage based on the

full-scale range, the transducer scale factor, and the Upscale Direction. For a

mid-scale zero the ideal gap is the center of the range.

Adjust the Zero Position voltage. When this button is clicked a utility starts that

helps you set the direct zero position voltage. Since this utility provides active

feedback from the 3500 rack, a connection with the rack is required. Refer to

Section 5.2 (Adjusting the Scale Factor and the Zero Position).

Transducer

1900/65A-01-01-02-00-00 The following transducer types are available for the Thrust Position Channel (non

barrier I/O module):

3300 – 5mm Proximitor

3300 – 8mm Proximitor

7200 – 5mm Proximitor

7200 – 8mm Proximitor

7200 – 11mm Proximitor

7200 – 14mm Proximitor

3000 (-18V) Proximitor

3000 (-24V) Proximitor

3300 RAM Proximitor

3300 – 16mm HTPS

Nonstandard

The following transducer types are available for the Thrust Position Channel

(barrier I/O module):

3300 – 5mm Proximitor

3300 – 8mm Proximitor

7200 – 5mm Proximitor

7200 – 8mm Proximitor

3300 RAM Proximitor

Nonstandard

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen