Bently turbine safety monitoring TSI 3500/15-05-05-00 power module

Product name:Bently turbine safety monitoring TSI 3500/15-05-05-00 power module

Product model:3500/15-05-05-00

Quantity: inventory

Warranty: We provide warranty service for 3500/15-05-05-00

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

3500/15-05-05-00 The following sections will describe how to test alarms, verify channels, verify filter

corner frequencies, and test OK limits for channels configured as Velocity. The

output values and alarm setpoints are verified by varying the input signal level

and observing that 3500/15-05-05-00 the correct results are reported in the Verification screen on

the test computer.

 

brand Product Name Product model Order No
BENTLY modular 3500/15-05-05-00 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1806092-3929

 

3500/15-05-05-00 The general approach for testing alarm setpoints is to simulate the Velocity signal

with a function generator and power supply. The alarm levels are tested by

varying the output from the test equipment and observing that the correct results

are reported in the Verification screen on the test computer. It is only necessary

to test those alarm parameters that are configured and being used. 3500/15-05-05-00 The general

test procedure to verify current alarm operation will include simulating a

transducer input signal and varying this signal:

  1. to exceed over Alert/Alarm 1 and Danger/Alarm2 Setpoints, and
  2. to drop below any under Alert/Alarm 1 and Danger/Alarm 2 Setpoints,

and

  1. to produce a nonalarm condition.When varying the signal from an alarm condition to a nonalarm condition, alarm

    hysteresis must be considered. Adjust the signal well below the alarm setpoint for

    the alarm to clear.

    3500/15-05-05-00 Direct

    1. Disconnect PWR / B, COM, and SIG / A (PWR, COM / A, and SIG / B for TMR

    I/O) field wiring from the channel terminals on the I/O module.

    1. Connect test equipment:

    For Seismoprobe:

    Connect test equipment and run software as described in section 5.1.7.1

    (Test Equipment and Software Setup – Velocity), use the setup shown on

    page 173 (Seismoprobe Test Setup). If no filtering has been configured,

    leave the frequency of the function generator set to 100 Hz. If filtering is

    configured, the needed frequency can be calculated from the following

    formula:

    Frequency = (0.89 × HPF) + (0.1575 × LPF)

    HPF = High-pass Filter Corner Frequency

    LPF = Low-pass Filter Corner Frequency

    If no filtering is configured, set the frequency of the function generator to

    100 Hz.

    If a Low-pass Filter is configured 3500/15-05-05-00 and no High-pass Filter is configured, use

    the following to determine the HPF to use in the formula:

    – If the units are RMS, use a HPF of 10 Hz. For any other

    configuration, use a HPF of 3 Hz.

    If a High-pass Filter is configured and no Low-pass Filter is configured, use

    a LPF of 5,500 Hz.

    Set the frequency of 3500/15-05-05-00 the function generator to this new value. The above

    is done to obtain a test frequency in the center of the channel frequency

    range.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen