3500/22M 3500/22-01-01-00 Bently Transient Data Interface

Product name:3500/22M 3500/22-01-01-00 Bently Transient Data Interface

Product model:3500/22-01-01-00

Quantity: inventory

Warranty: We provide warranty service for 3500/22-01-01-00

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

3500/22M 3500/22-01-01-00 The general approach for testing OK limits is to input a DC voltage and adjust it

above the Upper OK limit and below the Lower OK limit. This should cause a not

OK condition and cause the OK Relay to change state. 3500/22M 3500/22-01-01-00 The Upper and Lower OK

limits are displayed in the Verification screen on the test computer.

 

brand Product Name Product model Order No
BENTLY modular 3500/22-01-01-00 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1806092-3929

 

  1. Disconnect PWR, COM, 3500/22M 3500/22-01-01-00 and SIG field wiring from the channel terminals on

the I/O module.

  1. Connect test equipment and run software as described in Section 5.1.8.1

(Test Equipment and Software Setup – Acceleration).

  1. Bypass all other configured channels.
  2. Adjust the power supply voltage to -7.00 Vdc.
  3. Press the RESET switch on the Rack Interface Module (RIM). 3500/22M 3500/22-01-01-00 Verify that the

monitor OK LED is on and that the Channel OK State line in the Channel

Status section of the Verification Display screen reads OK.

  1. Verify that the OK relay on the Rack Interface I/O Module indicates OK

(energized). See 3500/20 Rack Interface Module manual, part #129768-01.

  1. Increase the power supply voltage (more negative) until the OK LED just

goes off (upper limit). Verify that the Channel OK State line on the

Verification screen reads not OK and that the OK Relay indicates not OK.

Verify that the Upper OK limit voltage displayed on the Verification screen

is equal to or more positive than the input voltage.

  1. Decrease the power supply voltage (less negative) to -7.00 Vdc.
  2. 3500/22M 3500/22-01-01-00 Press the RESET switch on the Rack Interface Module (RIM). Verify that the

OK LED comes back on and the OK relay energizes. Verify that the

Channel OK State line in the Channel Status section reads OK.

  1. Gradually decrease the power supply voltage (less negative) until the OK

LED just goes off (lower limit). Verify that the Channel OK State line in the

Channel Status section reads not OK and that the OK Relay indicates not

3500/22M 3500/22-01-01-00 Verify that the Lower OK limit voltage displayed on the Verification

screen is equal to or more negative than the input voltage.

  1. Increase the power supply voltage (more negative) to -7.00 Vdc.
  2. Press the RESET switch on the Rack Interface Module (RIM). Verify that the

OK LED comes back on, the OK relay energizes, and the Channel OK State

line in the Channel Status section reads OK.

  1. If you can’t verify any configured OK limit, go to Section 5.1.10 (If a Channel

Fails a Verification Test).

  1. Disconnect the power supply and multimeter and reconnect the PWR,

COM, and SIG field 3500/22M 3500/22-01-01-00 wiring to the channel terminals on the

Proximitor/Seismic I/O Module. Press the RESET switch on the Rack

Interface Module (RIM) and verify that the OK LED comes on and the OK

relay energizes.

  1. Repeat steps 1 through 14 for all configured channels.
  2. Return the bypass switch for all configured channels back to their original

setting

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 180 6092 3929
Mail: 2235954483@qq.com
Contact: Chen