Bently card module 3500/50-01-00-01 front and rear backplane

Product name:Bently card module 3500/50-01-00-01 front and rear backplane

Product model:3500/50-01-00-01

Quantity: inventory

Warranty: We provide warranty service for 3500/50-01-00-01

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

3500/50-01-00-01 Transducer Jumper Status (on I/O Module)

Returns the position of the Transducer Jumper on the Proximitor/Seismic I/O

Module. Refer to Section 4.1 (Setting the I/O Jumper) for the function of this

jumper.

Alarm Mode

Latching

Once an alarm is active, it will remain active even after the proportional value

drops below the configured setpoint level. 3500/50-01-00-01 The channel will remain in alarm

until it is reset using one of the following methods:

– the reset switch on the front of the Rack Interface Module

– the contact on the Rack Interface I/O Module

– the Reset button in the Operator Display Software

– the reset command through the Communication Gateway Module

– the reset command through the Display Interface Module

– the reset command in the Rack Configuration Software

 

brand Product Name Product model Order No
BENTLY modular 3500/50-01-00-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

Nonlatching

When an alarm is active, it will go inactive as soon as the proportional value

drops below the configured setpoint level.

3500/50-01-00-01 Alert should be the first level alarm that occurs when the transducer signal

level exceeds the selected value. Danger should be the second level alarm

that occurs when the transducer signal level exceeds the selected value.

The Alert and Danger values are set on the Setpoint screen.

3500/50-01-00-01 Barriers

Select the MTL 796(-) Zener External option, or Galvanic Isolators if external

safety barriers are connected between the monitor and the transducer. If using

an Internal Barrier I/O Module, select the internal option. These devices are

used to restrict the amount of energy that can flow into a hazardous area.

OK Mode

Latching

If a channel is configured for Latching OK, once the channel has gone not

OK the status stays not OK until a reset is issued. 3500/50-01-00-01 Reset a latched not OK by

using one of the following methods:

– the reset switch on the front of the Rack Interface Module

– the contact on the Rack Interface I/O Module

– the Reset button in the Operator Display Software

– the reset command through the Communication Gateway Module

– the reset command through the Display Interface Module

– the reset command in the Rack Configuration Software

Nonlatching

If a channel is configured for Nonlatching OK, the OK status of that channel

will track the defined OK status of the transducer.

3500/50-01-00-01 Timed OK Channel Defeat

An option that prevents a channel from returning to an OK status until that

channel’s transducer has remained in an OK state for the specified period of

time. If the option is enabled, the time is set to 60 seconds. The option protects

against false trips caused by intermittent transducers.

3.1.6 Acceleration Channel Options

This section discusses the Configuration Considerations and the Rack

Configuration Software screens associated with the Acceleration Channel.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen