3500/53-03-00 Used to adjust the Scale Factor for standard transducers. If Non-standard is

selected as the transducer type, the Scale Factor and the OK Limits can be

adjusted. The Non-standard transducer’s scale 3500/53-03-00 factor must be between 90

and 575 mV/mil. Also, there must be at least 2 volts between the Upper and

Lower OK Limits.

 

brand Product Name Product model Order No
BENTLY modular 3500/53-03-00 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

3500/53-03-00 Alarm Mode

Latching

Once an alarm is active it will remain active even after the proportional value

is no longer in alarm. The alarm state will continue until the channel is reset.

See Page 46.

Nonlatching

When an alarm is active, 3500/53-03-00 it will go inactive as soon as the proportional value

is no longer in alarm.

Alert is the first level alarm that occurs when the transducer signal level

exceeds the selected value. Danger is the second level alarm that occurs

when the transducer signal level exceeds the selected value. The Alert and

Danger values are set on the Setpoint screen.

3500/53-03-00 Barriers

For Seismoprobes, select the MTL 764(-) Zener External option if external safety

barriers are connected between the monitor and the transducer. For Velomitor,

select the MTL 787(-) Zener External option if external safety barriers are being

used. If using an Internal Barrier I/O Module for Velomitor, select the internal

option. These devices are used to restrict the amount of energy that can flow

into a hazardous area.

OK Mode

Latching

If a channel is configured for Latching OK, once the channel has gone not

OK, the status stays not OK until a reset is issued. See page 47.

Nonlatching

If a channel is configured for Nonlatching OK, the OK status of that channel

will track the defined OK status of the transducer.

Timed OK Channel Defeat

An option that prevents a channel from returning to an OK status until that

channel’s transducer has remained in an OK state for the specified period of

time. If the option is enabled, the time is set to 30 seconds. This option prevents

false trips caused by intermittent transducers.

3.2 Setpoints

3500/53-03-00 This section specifies the available setpoints for each type of channel. A setpoint

is the level within the full-scale range that determines when an alarm occurs.

The 3500 Monitoring System allows Alert/Alarm 1 setpoints to be set for every

proportional value on each channel. 3500/53-03-00 The channel will drive an Alert/Alarm 1

indication if one or more of the channel proportional values exceeds its setpoints.

The 3500 Monitoring System also allows up to four Danger/Alarm 2 setpoints

(two over setpoints and two under setpoints) to be set for up to two of the

proportional values. You may select any two of the available proportional values

for the channel.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen