Bently Navada 140482-02 3500/64 I/O Module External Termination

Product name:Bently Navada 140482-02 3500/64 I/O Module External Termination

Product model:3500/64 140482-02

Quantity: inventory

Warranty: We provide warranty service for 3500/64 140482-02

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

3500/64 140482-02 The general approach for testing these parameters is to simulate the Thrust

Position and Differential Expansion signal with a power supply. The output

values are verified by varying the input DC 3500/64 140482-02 voltage and observing that the correct

results are reported in the Verification screen on the test computer.

 

brand Product Name Product model Order No
BENTLY modular 3500/64 140482-02 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

  1. 3500/64 140482-02 Disconnect PWR, COM, and SIG field wiring from the channel terminals on

the I/O module.

  1. Connect test equipment and run software as described in Section 5.1.6.1

(Test Equipment and Software Setup – Thrust Position and Differential

Expansion).

  1. Adjust the power supply to produce a voltage equal to -18.00 Vdc on the Gap

bar graph display. Verify that the Gap bar graph display and the Current

Value Box is reading ±1 % of -18.00 Vdc. If the recorder output is configured,

refer to Section 5.1.10 (Verify Recorder Outputs) for steps to verify the

recorder output.

  1. Adjust the power supply to produce a voltage 3500/64 140482-02 equal to mid-scale on the Gap

bar graph display. Verify that the Gap bar graph and Current Value Box is

reading ±1 % of the mid-scale value. If the recorder output is configured,

refer to Section 5.1.10 (Verify Recorder Outputs) for steps to verify the

recorder output.

  1. If the reading does not meet specifications, check that the input signal is

correct. If the monitor still does not meet specifications or fails any other part

of this test, go to Section 5.1.11 (If a Channel Fails a Verification Test).

  1. Disconnect the test equipment and reconnect the PWR, COM, and SIG field

wiring to the channel terminals on the I/O module. Verify that the OK LED

comes on and the OK relay energizes. Press the RESET switch on the Rack

Interface Module (RIM) to reset the OK LED.

  1. 3500/64 140482-02 Repeat steps 1 through 6 for all configured channelsThe general approach for testing OK limits is to input a DC voltage and adjust it

    above the Upper OK limit and below the Lower OK limit. This will cause a

    channel not OK condition and the OK Relay to change state (de-energize). The

    Upper and Lower OK limits are displayed in the Verification screen on the test

    computer.

    1. Disconnect PWR, COM, and SIG field wiring from the channel terminals on

    the I/O module.

    1. Connect test equipment and run software as described in Section 5.1.6.1

    (Test Equipment and Software Setup – Thrust Position and Differential

    Expansion).

    1. Bypass all other configured channels.
    2. Adjust the power supply voltage to -7.00 Vdc.
    3. Press the RESET switch on the Rack Interface Module (RIM). Verify that the

    monitor OK LED is on and that the Channel OK State 3500/64 140482-02 line in the Channel

    Status box of the Verification screen reads OK.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen