Once a 3500 Monitoring System is operating, it continuously measures and
monitors a variety of supervisory parameters. The boards and components
inside of 3500 modules cannot be repaired in the field and require no calibration.
This section provides information for common tasks required under normal
operating condititions. For procedures that require more detailed information,
refer to the reference manuals listed in Reference manuals for 3500 modules on
page iv.
This section includes the following topics:
- Changing configuration
- Replacing modules
- Verifying channels
Changing configuration
The process of setting system, module, and channel options so that all the
modules in the 3500 rack work together is called configuration. These settings
are established and adjusted by using the 3500 Rack Configuration program.
Configuration settings are usually protected by security settings. The security
setting for a typical 3500 Monitoring System that is operating normally is
ìChange Setpoints in Program Modeî. This section shows how to adjust
setpoints. To change other configuration settings, refer to the 3500 Monitoring
System Rack Configuration and Utilities Guide, part number 129777-01.
To adjust alarm setpoints
- Place the rack in program mode by using the key switch on the Rack
Interface Module.
- In the 3500 Rack Configuration program, click the Setpoints pushbutton.Click on the monitor module to be adjusted.
- The Configuration Setpoint dialog for that monitor module will appear.
- Select the monitor channel to be adjusted in the Monitor Channel list box.
- For all measurement parameters except phase, adjust the setpoint level by
dragging the bar in the bar graph or by entering a value in the text box above
or below the parameter.
Notice that setpoints can be adjusted only for those parameters that are
enabled and that some parameters have both upper and lower setpoint
values. Parameters are enabled or disabled by using the Channel Option
screen. Refer to the 3500 Monitoring System Rack Configuration and
Utilities Guide for more information.
- For phase setpoints, enter the values for the beginning and ending setpoint in
the text boxes below the phase diagrams.
- Apply the adjusted setpoints to the rack by clicking OK and then downloading
the revised configuration to the rack
brand | Product Name | Product model | Order No |
BENTLY | modular | 125388-01 125388-01H | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
The boards and components inside of 3500 modules cannot be repaired in the
field and require no calibration. For 3500 modules that are not operating
properly, use the information in this section to replace the module with a spare
and then contact your local Bently Nevada representative for information about
returning the faulty module for failure analysis.
Replacing a main module
- Save the configuration of the module to be replaced.
3500 modules must have valid configuration settings in order to operate
properly. Replacement modules are not configured. By saving the
configuration, you can download the original configuration settings to the
replacement module.
The 3500 Monitoring System Configuration and Utilities Guide, part number
129777-01, shows how to save configuration files.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen