Install the upgrade firmware IC into the PWA. Be sure to match the notched end

of the IC to the notched end of the socket. Ensure that the IC is firmly seated in

the socket.

Top Shield Replacement

Replace the top shield. Position the notch on the top shield so that it is at the top

left corner of the module as shown in the diagram under ìTop Shield Removalî.

Align the holes in the top shield with the standoffs and press down around each

standoff until they snap in place.

brand Product Name Product model Order No
BENTLY modular 133300-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

This section describes how to troubleshoot a problem with the Rack Interface

Module or the I/O modules by using the information provided by the verification

screen, the LEDs, the System Event List, and the Alarm Event List. You can

display the verification screen and the two event lists by using the Rack

Configuration Software.

Verification

To perform the Rack Interface Module’s verification:

  1. Connect a computer running the Rack Configuration Software to the 3500

rack (if needed).

  1. Select Utilities from the main screen of the Rack Configuration Software.
  2. Select Verification from the Utilities menu.
  3. Select the Rack Interface Module and select the channel you want to verify.
  4. Press the Verify button.
  5. Select the Front Port or the Rear Port to get the status.
  6. The Module OK State will show the Rack Interface Module’s status and the

Channel OK State will show the channel’s status.

Sequence Number: The number of the event in the System Event List (for

example 123).

Event Information: The name of the event (for example Device Not

Communicating).

Event Number: Identifies a specific event.

Class: Used to display the severity of the event.

Severe/Fatal Event

Potential Problem Event

Typical Logged Event

Reserved

Event Date: The date the event occurred.

Event Time: The time the event occurred.

Event Specific: Provides additional information for the events that use

this field.

Slot: Identifies the module that the event is associated with.

If a half-height module is installed in the upper slot or a

full-height module is installed, the field will be 0 to 15.

If a half-height module is installed in the lower slot,

then the field will be 0L to 15L. For example, the

module is installed in the lower position of slot 5 (5L)