The following System Event List Messages may be placed in the list by the Rack

Interface Module and are listed in numerical order. If an event marked with a star

(*) occurs the…

ï Host link on the back of the Rack Interface I/O Module supplying the

message will not communicate with the host computer

ï other Rack Interface Modules in the daisy chain will still be able to

communicate with the host computer

ï both ports of the Data Manager I/O Module will stop communicating

If you are unable to solve any of these problems, contact your nearest Bently

Nevada Corporation office.

Flash Memory Failure

Event Number: 11

Event Classification: Potential Problem

Action: Replace the Rack Interface Module as soon as possible.

Real Time Clock Failure

Event Number: 12

Event Classification: Severe/Fatal Event

Action: Replace the Rack Interface Module immediately.

Internal Network Failure

Event Number: 30

Event Classification: Severe/Fatal Event

Action: Replace the Rack Interface Module immediately.

Resync Internal Network (Resynchronize Internal Network)

Event Number: 31

Event Classification: Potential Problem

Action: Check to see if one of the following components is faulty:

ï Rack Interface Module

ï Rack backplane

Device Not Communicating

Event Number: 32

Event Classification: Potential Problem

Action: Check to see if one of the following components is faulty:

ï Module installed in the slot

ï Rack backplane

Device Is Communicating

Event Number: 33

Event Classification: Potential Problem

Action: Check to see if one of the following components is faulty:

ï Module installed in the slot

ï Rack backplane

brand Product Name Product model Order No
BENTLY modular 133388-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

Config Token Acquired (Configuration Token Acquired)

Event Number: 50

Event Classification: Typical logged event

Event Specific: Front,

Back,

DM1 (Data Manager port 1),

DM2 (Data Manager port 2),

ComGate (Communication Gateway)

The specified port can download configuration, change setpoints, set

software switches, enable/disable Rack Alarm Inhibit, enable/disable

Trip Multiply, or perform Rack Reset.

Action: No action required.

Config Token Released (Configuration Token Released)

Event Number: 51

Event Classification: Typical logged event

Event Specific: Front,

Back,

DM1 (Data Manager port 1),

DM2 (Data Manager port 2),

ComGate (Communication Gateway)

The specified port can no longer download configuration, change

setpoints, set software switches, enable/disable Rack Alarm Inhibit,

enable/disable Trip Multiply, or perform Rack Reset.

Action: No action required.

Config Token Expired (Configuration Token Expired)

Event Number: 52

Event Classification: Potential Problem

Action: Check to see if one of the following components is faulty:

ï Connection between the Rack Interface Module and the

computer running the Rack Configuration Software

ï Rack Interface Module

ï Computer running the Rack Configuration Software

Config Token Override (Configuration Token Override)

Event Number: 53

Event Classification: Typical Logged Event

Action: No action required.

Fail Relay Coil Sense

Event Number: 55

Event Classification: Potential Problem

Action: Check to see if the Rack Interface I/O Module is installed. If

installed, check to see if one of the following components is faulty:

ï Rack Interface Module

ï Rack Interface I/O Module