Description

Used to select whether the functions of the channel will be turned on (; )

or off .

Options

A button to display the configuration options for the selected channel

type.

Transducer OK % Comparison (Zero Speed and Reverse Rotation Only)

Used to enable an additional OK check for

Zero Speed Tachometer dual transducer

inputs. When enabled, this check requires

that the two inputs be within a configurable

percentage (1 to 10 % of full-scale range)

of one another before driving an alarm. This check is disabled below 1

rpm and above 100 rpm.

When using a single event for speed monitoring and when the machine

can ramp down quickly, a difference can occur in a monitored speed

causing it to be outside the % compare window.

 

brand Product Name Product model Order No
BENTLY modular 133819-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

This section discusses the configuration considerations and lists the channel

configuration options used to configure Tachometer Channel types.

Channel Configuration Considerations

Consider the following items before configuring Tachometer channel types:

  • Internal Barrier I/O Modules and External barriers are not currently

supported with 7200 11mm and 14mm, 3300 16 mm HTPS, and Magnetic

Pickup Proximity Transducers.

  • The 3500 Tachometer does not support the 3000 Proximitor Transducer.
  • Setpoints may only be set on proportional values that are enabled.
  • When a full-scale range is modified, the setpoints associated with the

proportional value should be re-adjusted.

  • Alarming is not provided on the Peak Speed proportional value. Peak

Speed is for display purposes only.

  • Alarming is not provided on the Gap proportional value (where available).

Gap is for display purposes only.

  • Passive magnetic pickups are not recommended for monitoring at low

speeds because of the small signal amplitude provided.

  • Proportional value update rate and alarm response times are dependent

upon input frequency. At low input frequencies, these times may be very

slow.

These fields indicate which channel you are configuring.

Channel

The number of the channel being configured (1 or 2).

Slot

The location of the monitor in the 3500 rack (2 through 15).

Rack Type

The type of Rack Interface Module installed in the rack (Standard or

TMR).

Enable

An enabled proportional value specifies that the value will be provided by the

channel (9 enabled, 2disabled). Proportional values that have a checkbox

(9 ) are always enabled.