147663-01 Bently Nevada Monitor card

Product name:Bently Nevada 147663-01

Product model:147663-01

Quantity: inventory

Warranty: We provide warranty service for 147663-01

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

I/O Module Mismatch

Event Number: 62

Event Classification: Severe / Fatal Event

Action: Verify that the type of I/O module installed matches what was

selected in the software. If the correct I/O module is installed, there

may be a fault with the Monitor Module or the Monitor I/O module.

Monitor Module will stop alarming.

I/O Module Compatible

Event Number: 63

Event Classification: Severe / Fatal Event

Action: Verify that the type of I/O module installed matches what was

selected in the software. If the correct I/O module is installed, there

may be a fault with the Monitor Module or the Monitor I/O module.

Fail Main Board +5V-A (Fail Main Board +5V – upper Power Supply)

Event Number: 100

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the upper slot

Pass Main Board +5V-A (Pass Main Board +5V – upper Power Supply)

Event Number: 101

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the upper slot

Fail Main Board +5V-B (Fail Main Board +5V – lower Power Supply)

Event Number: 102

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the lower slot

 

brand Product Name Product model Order No
BENTLY modular 147663-01 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

Pass Main Board +5V-B(Pass Main Board +5V – lower Power Supply)

Event Number: 103

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the lower slot

* Fail Main Board +5V-AB (Fail Main Board +5V – upper and lower Power

Supplies)

Event Number: 104

Event Classification: Severe/Fatal Event

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the upper slot

the Power Supply installed in the lower slot

Monitor Module will stop alarming.

Pass Main Board +5V-AB (Pass Main Board +5V – upper and lower Power

Supplies)

Event Number: 105

Event Classification: Severe/Fatal Event

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the upper slot

the Power Supply installed in the lower slot

Fail Main Board +15V-A (Fail Main Board +15V – upper Power Supply)

Event Number: 106

Event Classification: Potential Problem

Action: Verify that noise from the power source is not causing the problem. If

the problem is not caused by noise, check to see if one of the

following components is faulty:

the Monitor Module

the Power Supply installed in the upper slot

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen

 

135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required