Description
3500/40-03-01 Provides additional information of the events that use this
field.
Slot: Indicates the module with which the event is associated. If a
half-height module is installed in the upper slot or a fullheight module is installed, the field will be 0 to 15. If a halfheight module is installed in the lower slot then the field will
be 0L to 15L. For example, a module installed in the lower
position of slot 5 would be 5L.
The Hazardous Gas Detection Monitor may place the following event
messages, which are listed in numerical order, in the System Event List. If
an event marked with a star (*) occurs, the monitor will stop alarming. If
you are unable to solve any problems, contact your nearest Bently
Nevada, LLC office for assistance.
3500/40-03-01 Flash Memory Test
Event Number: 11
Event Classification: Sever/Fatal Event
Action:
Replace the Monitor Module.
* EEPROM Memory Failure
Event Number: 13
Event Classification: Potential Problem or Severe/Fatal Event
Action:
Replace the Monitor Module as soon as possible.
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/40-03-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
Device Not Communicating
Event Number: 32
Event Classification: Potential Problem
Action:
Check to see if one of the following components is faulty:
• the Monitor Module
• the rack backplane
Device Is Communicating
Event Number: 33
Event Classification: Potential Problem
Action:
Check to see if one of the following components is faulty:
• the Monitor Module
• the rack backplane
* Neuron Failure
Event Number: 34
Event Classification: Severe / Fatal Event
Action:
Replace the Monitor Module immediately.
Monitor Module will stop alarming.
* I/O Module Mismatch
Event Number: 62
Event Classification: Severe / Fatal Event
Action:
Verify that the type of I/O module installed matches what was
selected in the software. If the correct I/O module is installed, there
may be a fault with the Monitor Module or the Monitor I/O module.
Monitor Module will stop alarming.
I/O Module Compatible
Event Number: 63
Event Classification: Severe / Fatal Event
Action:
Verify that the type of I/O module installed matches what was
selected in the software. If the correct I/O module is installed, there
may be a fault with the Monitor Module or the Monitor I/O module.
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required