Description
3500/42 140482-01 Disable Test Signal
Event Number: 482
Event Classification: Typical Logged Event
Action:
No action required.
Setpoint Updated
Event Number: 511
Event Classification: Typical logged event
Action:
No action required.
Enable/Disable Group Reset
Event Number: 521
Event Classification: Typical logged event.
3500/42 140482-01 Action:
No action required.
*I/O Module Removed
Event Number: 550
Event Classification: Typical logged event
Action:
No action required.
Monitor Module will stop alarming.
* Possible Open XDCR
Event Number: 551
Event Specific: Ch x
Event Classification: Severe/Fatal Event
Action:
Possible open in the signal path between the sensor and where the
signal is conditioned, or possible leads swapped. The possible
location for the problem may be:
• field wiring
• I/O module
• Monitor module
Monitor may stop alarming.
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/42 140482-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
Possible Wiring Fault
Event Number: 552
Event Specific: Ch x
Event Classification: Severe/Fatal Event
Action:
Possible open in the signal path between the sensor and where the
signal is conditioned. The possible location for the open may be:
• field wiring
• I/O module
• Monitor module
Monitor may stop alarming.
Xdcr OK
Event Number: 553
Event Classification: Potential Problem
Action:
The sensor may have failed in the past and has now recovered.
Check if there is other associated event messages. If so follow the
action for those events, such as troubleshoot wiring, sensor,
channel.
* I/O Calibration Failure
Event Number: 560
Event Classification: Severe/Fatal Error
Action:
Replace the monitor module as soon as possible.
Monitor will stop alarming.
* ADC Failure
Event Number: 562
Event Classification: Severe/Fatal Error
Action:
Replace the monitor module immediately. Monitor module will stop
alarming.
* Enable Haz Gas Calibration
Event Number: 620
Event Classification:
Description: Typical logged event, during calibration.
Action:
No action required.
Monitor will stop alarming while calibration is enabled. Be sure to
complete a successful calibration such that Disable Haz Gas
Calibration follows Enable Haz Gas Calibration
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required