Description
3500/50 136703-01 After the probe is secured in position, the probe cable must be securely fastened to prevent fatigue failure caused by oil flow, moving air, or singular stress conditions. A clip or cable holding device will work as long as it does not exert enough force on the cable to cause the FEP insulation to cold flow. Cold flow is change in dimension or distortion caused by the sustained application of force.
3500/50 136703-01 Sometimes it is necessary to seal around the probe cable. Sealing creates a special problem, because the cable is insulated with FEP which will cold flow and cannot be subjected to high pressure exerted by some gland seals. If the pressure differential across the seal area is one atmosphere or less, a simple seal (such as duct seal putty) can be used. If the differential pressure is greater than one atmosphere, a special probe must be used. Contact your nearest Bently Nevada office for more information.
Before the probe is installed, make sure its electrical length is equal to the electrical length required by the Proximitor.
Before routing the cable, insert an identification label (provided by the user) under the clear FEP sleeve at the end of the cable, if desired. Secure the label by applying heat to shrink the tubing. The heat source should not exceed 300° F (149° C).
brand | Product Name | Product model | Order No |
BENTLY | modular | 3500/50 136703-01 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
The cable should be routed inside conduit connected to the enclosure which contains the Proximitor. Where the cable is installed in a conduit, care must be taken not to rub or cut the cable on sharp or rough surfaces. Protect the connector from contamination by covering or taping prior to pushing through the conduit.
If it is undesirable or not possible to route the cable inside conduit, armored cable should be used. Use clips or similar devices to secure the armored cable to supporting surfaces. Route the cable through protected areas to reduce the chance of physical abuse. The armor should be terminated at the Proximitor enclosure.
If the connector on the cable ever needs replacement, check with Bently Nevada Corporation for installation procedures, connector part numbers, and the required tools.
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact Us:+86 18106937731
Whatapp:+86 15359293870
Email: geabbdcs@gmail.com / 2872270648@qq.com
Contact Person: Chen
135785-01 3500/93 Display Unit, non backlighted
135785-02 3500/93 Display Unit, back-lighted
137412-01 3500/93 Manual
135799-01 3500/93 Display Interface Module
135799-02 3500/93 Display Interface Module
(use with A05 option only)
135813-01 3500/93 Display Interface I/O
Module
136634-0010-01 10 Foot (3 metres) Cable (PVC)
136634-0050-01 50 Foot (15 metres) Cable (PVC)
136634-0050-02 50 Foot (15 metres) Cable
(Teflon? )
136634-0100-01 100 Foot (30 metres) Cable (PVC)
136634-0100-02 100 Foot (30 metres) Cable
(Teflon? )
130121-02-01 500 Foot (152 metres) Extension
Cable (PVC)
130121-02-02 500 Foot (152 metres) Extension
Cable (Teflon? )
02200271 External Power Supply for 115 Vac
02200272 External Power Supply for 230 Vac
138227-01 Cable Adapter
146085-01 Power Cable
137224-01 System Mounting Assembly
(sheet metal for A01 & A05
options)
04309007 4-40 X 0.63 Phillips head screw for
System Mounting Assembly, 4 are
required