The 1C31179G02 register at address 12 (C in Hex) is for diagnostics and is a read-only register.
The overcurrent and undercurrent status bits may be read from this register. Table
7-5 shows the overcurrent and undercurrent bits for each channel. The overcurrent
bits are used for both the voltage groups and current groups. The undercurrent bits
only have meaning for the current group. The 1C31179G02 voltage output groups do not
implement the undercurrent bit.
The simultaneous setting of a channel’s overcurrent and undercurrent bits indicates
a loss of Field Card power supply for that channel. Overcurrent and undercurrent
bits indicate the output current status of this module and not the loop current.
brand | Product Name | Product model | Order No |
EMERSON | modular | 1C31179G02 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
The Contact Input Module, 1C31179G02 comprised of an Electronics module and Personality
module, provides 16 contact input current detecting channels with common returns.
The fifield side circuitry and terminal connections for three of these channels are
shown in Figure 8-2.
A +48V on-board power supply provides current limited contact wetting voltage if
the contact is open. If the contact closes, current is drawn from the +10V supply
which turns on the associated opto-isolator; thereby,1C31179G02 relaying a closed contact state
to the I/O bus. The opto-isolators and the isolation provided by the 10V and 48 Volt
power supply provide high dielectric isolation between the fifield side and the logic
or I/O bus side.
There are two methods of wiring fifield devices to the Contact Input Module
termination block, as shown in Figure 8-2. Each fifield contact may have a separate
input and return line as shown for channel 1. Alternatively, fifield contacts wired to
the same Contact Input Module may share a return line 1C31179G02 as shown for channels 2 and
- For either wiring method, do not tie the contact return line to earth ground or a
ground fault condition will occur as well as a degradation of the common mode
surge protection.
Debouncing of a contact input signal is done by an RC fifilter and digital debouncer
on the logic side. If a contact changes state for less than 3 msec, the change of state
will always be rejected. If the Contact changes state for more than 7 msec, the
change of state will always be accepted.
Ground fault detection circuitry on a Contact Input Module activates when an input
or return line for any channel fifinds a low impedance (<5 K ohms) path to earth
ground. A single ground fault wire will not cause an error in the point data, but
multiple ground faults (if they include input and return lines) could cause faulty data
(that is, channels appearing as if contacts are closed when they are really open).
When a ground fault occurs, the external error LED lights, and the GND Fault bit
in the Status Register (Section 8-7) is set. If the GND Fault Attention Enable bit is
set in the Confifiguration Register (Section 8-7), a ground fault is seen as a
catastrophic error causing an attention status to be sent back to the Controller. See
Figure 8-2 for ground fault detection circuitry. The Contact Input Module is
applicable for CE Mark Certifified Systems.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen