Description
The 5X00481G04 Contact Input confifiguration (1C31233G04) provides 16 contact input current
detecting channels with common returns. The fifield side circuitry and terminal
connections for three of these channels are shown in Figure 21-4.
A +48V on-board power supply provides current limited contact wetting voltage if
the contact is open. If the contact closes, current is 5X00481G04 drawn from the +10V supply
which turns on the associated opto-isolator; thereby, relaying a closed contact state
to the I/O bus. The opto-isolators and the isolation provided by the 10V and 48 Volt
power supply provide high dielectric isolation between the fifield side and the logic
or I/O bus side.
brand | Product Name | Product model | Order No |
EMERSON | modular | 5X00481G04 | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
There are two methods 5X00481G04 of wiring fifield devices to the termination block as shown in
Figure 21-4. Each fifield contact may have a separate input and return line as shown
for channel 1. Alternatively, fifield contacts wired to the same module may share a
return line as shown for channels 2 and 3. For either wiring method, do not tie the
contact return line to earth ground or a ground fault condition will occur, as well as
a degradation of the common mode surge protection.
Ground fault detection circuitry on the Sequence of Events module with Contact
Inputs activates when the input or return line for any channel fifinds a low impedance
(<5 K ohms) path to earth ground. A single wire with a ground fault will not cause
an error in the point data, but multiple ground faults, if they include input and return
lines, could cause 5X00481G04 faulty data (that is, channels appearing as if their contacts are
closed when they are really open)
When a ground fault occurs, the external error LED lights, and the GND Fault bit
11 in the Status Register is set. If the GND Fault Attention Enable bit 8 is set in the
Confifiguration Register, a ground fault is seen as a catastrophic error causing an
attention status to be sent back to the Controller. See Figure 21-4 for ground fault
detection circuitry.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen