Emerson HD22010-2 Inductor expander

¥580.00

Product name:Emerson HD22010-2 Inductor expander

Product model: HD22010-2

 

HD22005-3A and HD11010-3A rectifiers, using the advanced power technology and process, is designed for the DC systems in various transformer substations, hydropower plants, power plants and other DC power supply application. It features high efficiency, high power density, high reliability, intelligent control and aesthetic appearance.

78 in stock

Category: SKU: HD22010-2
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

It is highly recommended that the maximum distance of the stepper valve harness length between the valve and the XEV22D controller must not exceed 30 feet (10 meters). If the valve harness length must be extended beyond 30 feet (10 meters), Emerson Retail Solutions provides an Inductor Extender (P/N 335-3500) for use with Sporlan Valves ONLY. The Inductor Extender (P/N 335-3500) is ONLY for use with Sporlan Bipolar 4-wire stepper valves with 100 ohm or 75 ohm phase resistance.

 

When using the Inductor Extender, the XEV22D controller “CPP” parameter setting MUST be less than 20; otherwise the Valve, Controller, and/or Inductor Extender will be damaged or have its life expectancy drastically shortened. Refer to Table 4-4 for the list of the XEV series controller supported Sporlan Stepper valves. The Inductor Extender can ONLY be used with Sporlan Bipolar Stepper valves that have a setting of 16 or 12 in the “CPP” column.

 

 

brand Product Name Product model Order No
EMERSON modular HD22010-2 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

The recommended CPP parameter should NOT be increased to create AC voltage at the valve, if the valve harness length is over 30 feet, an Inductor Extender MUST be added into the 4-wire valve harness. When using the Inductor Extender (P/N 335-3500), any stepper valve harness extensions MUST not exceed 170 feet total length. Use 14 AWG wire for valve harness extensions in conduit. If the valve harness extension is not in con- duit, use 16 AWG or 14 AWG shielded cable with the shield terminated to an earth grounded chassis. For valve harness extensions over 100 feet, 14 AWG shielded cable is recommended.

 

Using an AC volt meter to measure voltage at the Valve will not produce accurate results with a voltage chopper constant current stepper valve drivers as used in XEV22D controllers. Instead, an AC current meter can be used to measure valve milliamps as a field verification method. If the current measurement using the method described below is less than the recommended value by more than 20%, the CPP parameter may be increased by up to 2 (12 to 14 or 16 to 18).

 

The CPP parameter MUST be less than 20 when using the Inductor Extender (P/N 335-3500). For a CPP parameter of 12, the measured current should be near 120 mA AC, for a CPP setting of 16, the measured current should be near 160 mA AC.