FOXBORO P0914YZ FPS400-24 P0922YU controller spare parts

¥980.00

FOXBORO P0914YZ FPS400-24 P0922YU

Input/Output Range (Each Channel)
0 to 20.4 mA dc

Category: SKU: P0914YZ Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Data block DB1: AI data, type: REAL, interface with upper computer; DB2: AO data, type: REAL, interface with upper computer; DB3: DI data, type: BOOL, interface with upper computer; DB4: DO data, type: BOOL, interface with upper computer; DB5: Device running time and traffic accumulation, type: REAL, interface with upper computer; DB6: Alarm message, type: BOOL, interface with upper computer; DB7: Type: REAL, intermediate register; DB8: Type: INT, intermediate register; DB9: Type: WORD, intermediate register; DB10: Type: BOOL, intermediate register; DB11: Later used for communication with devices, such as MODBUS communication; DB100: used later as the background data block when calling the FB block; Zone M: also serves as an intermediate variable.

2. Unified program structure OB1: main program; OB100: initialization program (no need for main program call); OB35: 100ms (modifiable) interrupt (no need for main program call), can call PID module; OB80, OB82, OB85, OB86, OB87, OB121, OB122: Fault diagnosis module (without main program call or programming); FC1: System mode; FC2: Input processing; FC3: Output processing; FC4: Operation processing; FC5: Stop processing; FC6: Manual automatic switching; FC7:… FC100: Later used to establish some subroutines that can be called iteratively; FC105: System built-in, analog input subroutine (can be called in a loop); FC106: System built-in, analog output subroutine (can be called in a loop); Modbus communication (CP341): FB7: P_ RCV_ RK, FB8: P_ SND_ RK; Communication CP340: FB2: P_ RCV, FB3: P_ SND; General PID: use FB41; Temperature and humidity PID: use FB58; If the program block is duplicated with the system block, please avoid it. 3. DP slave station fault diagnosis: DP slave station must perform fault diagnosis and alarm, and FB125 can be used.

FBM201B Channel Isolated 8 Input 0-100 mV 21H-2Z1 B4 P0922YH
FBM201D Channel Isolated 8 Input 0-10 V 21H-2Z1 B4 P0922YK
FBM202 Channel Isolated 8 Input Thermocouple/mV 21H-2Z2 B4 P0926EQ
FBM203 Channel Isolated 8 Input RTD 21H-2Z3 B4 P0914SV
FBM204 4 Channel 0-20 In + 4 Channel 0-20 Out 21H-2Z4 B4 P0914SY
FBM205 Redundant 0-20 Combo Module 21H-2Z5 B4 P0914XG
FBM215/218 Compression Term Assembly, PolyAmide 21H-2Z15 B4 P0926SP
FBM218, Redundant Ready HART Output, 8 Channels 21H-2Z18 B4 P0922VW
FBM233, 10/100 Mbps Ethernet, Redundant 21H-2Z33 B4 P0926GX
FBM237 Channel Isolated 8 Output 0-20 mA 21H-2Z37 B4 P0914XS
FBM241c Ch Isolated CSense DI + External Source DO 21H-2Z41 B4 P0914WM
FBM241d Ch Isolated CSense DI + Internal Source DO 21H-2Z41 B4 P0914WP