Sale!

FX316 Emerson DXE-316 motor settings FX-316

¥580.00

Product name:FX316 Emerson DXE-316 motor settings FX-316

Product model: FX316

 

In order to comply with UL listing you must incorporate fuse protection for the incoming AC power with the minimum rating shown here. The AIC (Amperes Interrupting Capacity) rating is 5000 amps minimum for all FX drives.

78 in stock

Category: SKU: FX316
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

This parameter specifies the maximum velocity the FX Drive will accelerate to during the index. If the acceleration time, deceleration time and distance are very short, the motor may not reach the maximum velocity; however, the commanded position will be achieved.

 

For example, if you are setting up an FX-316 with a DXE-316 motor, the motors maximum velocity is 4,000 RPM. In the index screen you enter a maximum velocity of 1,800 RPM and a decel time of 2.0 seconds. The actual time the FX drive will take to decelerate the motor from 1,800 RPM to zero is found by multiplying 2.0 seconds by 1,800/4,000 or 0.9 seconds.

 

brand Product Name Product model Order No
EMERSON modular FX316 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

This parameter only appears in Feed To Sensor and Registration Indexes. When this parameter is set to “Yes” and you select Registration Index, the FX drive will accelerate to the Feed Velocity and continue at that velocity until a signal is received on the input line assigned to Input Function #16, Feed Sensor Ø. Once the signal is received, the FX drive will start the Distance/Velocity part of the index. If you select a Feed To Sensor Index, the FX drive will execute the distance part of the index.

 

When the motor reaches that distance, the drive will change to Feed Velocity until the input line assigned to Feed Sensor Ø is activated or the Sensor Limit Distance is exceeded. If this parameter is set to Yes and the parameter Feed To Sensor (1) is also set to Yes, the FX drive will continue at the feed velocity until either Feed Sensor Ø or 1 receives a valid input.