Description
GE General Electric Technical Specifications: IS200FHVBG1A
The Analog Current/Voltage Combination Input/Output module provides up to 4 differential
input current or voltage channels and 2 single-ended output channels with either current loop
outputs or voltage outputs. Each channel can be individually IS200FHVBG1A configured for the current or
voltage range, as applicable, required for your application. All module configuration is done
through software, except for a jumper required IS200FHVBG1A for selecting the current input mode. All ranges
can be configured using either the Logicmaster 90-30/20/Micro programming software
configurator function or the Series 90-30 Hand-Held Programmer.
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200FHVBG1A | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
Note that in this module’s description, the module will be simply referred to as the Analog Combo
Module.
Each analog input is capable of providing five input ranges (two voltage and three current),
which are:
0 to +10 volts (unipolar) – default range IS200FHVBG1A for both input and output channels.
–10 to +10 volts (bipolar)
0 to 20 mA
4 to 20 mA
4 to 20 mA Enhanced
The default input range is voltage mode 0 to +10 volts (unipolar) with user data scaled so that
0V corresponds to a count of 0 and 10V corresponds to a count of 32767.
Each analog output is capable of providing four output ranges (two voltage and two current):
0 to +10 volts (unipolar) – default range for both input and output channels.
–10 to +10 volts (bipolar)
0 to 20 milliamps
4 to 20 milliamps
Each output channel is capable of converting 15 to 16 bits (depending on the range selected) of
binary (digital) data to an analog output for use as required by your application. User data in
the%AI and %AQ registers is in a 16-bit 2’s complement format. In current modes, an open-wire
fault is reported to the CPU for IS200FHVBG1A each channel. The module can go to a known last state when
system power is interrupted. As long as user power is applied to the module, each output will
maintain its last value, or reset to the low end of the scale (range), as determined by how you have
configured the module.
Each output channel can be configured to operate in ramp mode using ladder logic. In ramp
mode, changes in %AQ data cause the corresponding output channel to ramp to the new %AQ
value. The ramp output consists of steps taken each millisecond until the final value is reached.
High and low alarm limits can be set for all input channels and an open-wire fault (current
output modes) is reported to the CPU for each output channel. All six analog channels may be
updated on every scan, depending on the scan time.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed
in a system are:
4 in a system using CPU Models 311, 313, or 323
8 in a system using CPU Model 331
32 in a system using CPU Models 340 and 341
64 in a system using CPU Models 350 – 364
Other Configuration Considerations
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load
requirements. The following table lists the specifications for this module. Note that test conditions,
unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen