GE IS200HSLAH5A high-speed serial link interface board

Product name:
GE IS200HSLAH5A high-speed serial link interface board

Product model: IS200HSLAH5A

Quantity: inventory

Part No./PN: IS200HSLAH5A

Warranty: We provide warranty service for IS200HSLAH5A

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

GE General Electric Technical Specifications: IS200HSLAH5A

The 489 is packaged in the standard GE Power Management SR series arrangement, which consists of a drawout unit and

a companion fixed case. The IS200HSLAH5A case provides mechanical protection to the unit, and is used to make permanent connections

to all external equipment. The only electrical components mounted in the case are those required to connect the unit to the

external wiring. Connections in the case are fitted with mechanisms required to allow the safe removal of the relay unit from

an energized panel, such as automatic CT shorting. The unit is mechanically IS200HSLAH5A held in the case by pins on the locking handle,

which cannot be fully lowered to the locked position until the electrical connections are completely mated. Any 489 can be

installed in any 489 case, except for custom manufactured units that are clearly identified as such on both case and unit,

and are equipped with an index pin keying mechanism to prevent incorrect pairings

 

brand Product Name Product model Order No
GE Fanuc Module card IS200HSLAH5A nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

To prevent unauthorized IS200HSLAH5A removal of the drawout unit, a wire lead seal can be installed in the slot provided on the handle as

shown below. With this seal in place, the drawout unit cannot be removed. A passcode or setpoint access jumper can be

used to prevent entry of setpoints but still allow monitoring of actual values. If access to the front panel controls must be

restricted, a separate seal can be installed on the outside of the cover to prevent it from being opened.

The 489 case, alone or adjacent to another SR unit, can be installed in a standard 19-inch rack panel (see Figure 2–1: 489

DIMENSIONS on page 2–1). Provision must be made for the front door to swing open without interference to, or from, adja

cent equipment. The 489 unit is normally mounted in its case when shipped from the factory and should be removed before

mounting the case in the supporting panel. Unit withdrawal is described in the next section.

After the mounting hole in the panel has been prepared, slide the 489 case into the panel from the front. Applying firm pres

sure on the front to ensure the front bezel fits snugly against the front of the panel, bend out the pair of retaining tabs (to a

horizontal position) from each side of the case, as shown below. The case is now securely mounted, ready for panel wiring.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de

The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed

in a system are:

4 in a system using CPU Models 311, 313, or 323

8 in a system using CPU Model 331

32 in a system using CPU Models 340 and 341

64 in a system using CPU Models 350 – 364

Other Configuration Considerations

When planning the module configuration for your application you must also consider the load

capacity of the installed power supply and the total load requirements of all modules that are

installed in the baseplate.

Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load

requirements. The following table lists the specifications for this module. Note that test conditions,

unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)

livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen