GE IS200ICBDH1ABB MARK VI CONTROL CARD

Product name:
GE IS200ICBDH1ABB MARK VI CONTROL CARD

Product model: IS200ICBDH1ABB

Quantity: inventory

Part No./PN: IS200ICBDH1ABB

Warranty: We provide warranty service for IS200ICBDH1ABB

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

GE General Electric Technical Specifications: IS200ICBDH1ABB

The IS200ICBDH1ABB provides four analog output channels, which when IS200ICBDH1ABB ordering, are selected to provide a full-scale range of either

0 to 1 mA (into a maximum 10 kΩ impedance), or 4 to 20 mA (into a maximum 600 Ω impedance). Each channel can be

configured to provide full-scale output sensitivity for any range of any measured parameter.

As shown in Figure 2–9: TYPICAL WIRING DIAGRAM on page 2–7, these outputs share one common return. The polarity

of these outputs must be IS200ICBDH1ABB observed for proper operation. Shielded cable should be used, with only one end of the shield

grounded, to minimize noise effects.

The analog output circuitry is isolated as a group with the Analog Input circuitry and the RTD circuitry. Only one ground ref

erence should be used for the three circuits. Transorbs limit this isolation to ±36 V with respect to the 489 safety ground.

 

brand Product Name Product model Order No
GE Fanuc Module card IS200ICBDH1ABB nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

The IS200ICBDH1ABB can monitor up to 12 RTD inputs for Stator, Bearing, Ambient, or Other temperature monitoring. The type of each

RTD is field programmable as: 100 Ω Platinum (DIN 43760), 100 Ω Nickel, 120 Ω Nickel, or 10 Ω Copper. RTDs must be

three wire type. Every two RTDs shares a common return.

The IS200ICBDH1ABB RTD circuitry compensates for lead resistance, provided that each of the three leads is the same length. Lead

resistance should not exceed 25 Ω per lead. Shielded cable should be used to prevent noise pickup in the industrial envi

ronment. RTD cables should be kept close to grounded metal casings and avoid areas of high electromagnetic or radio

interference. RTD leads should not be run adjacent to or in the same conduit as high current carrying wires

IMPORTANT NOTE: The RTD circuitry is isolated as a group with the Analog Input circuitry and the Analog Output

circuitry. Only one ground reference should be used for the three circuits. Transorbs limit this isolation to ±36 V with

respect to the 489 safety ground. If code requires that the RTDs be grounded locally at the generator terminal box,

that will also be the ground reference for the analog inputs and outputs.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de

The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed

in a system are:

4 in a system using CPU Models 311, 313, or 323

8 in a system using CPU Model 331

32 in a system using CPU Models 340 and 341

64 in a system using CPU Models 350 – 364

Other Configuration Considerations

When planning the module configuration for your application you must also consider the load

capacity of the installed power supply and the total load requirements of all modules that are

installed in the baseplate.

Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load

requirements. The following table lists the specifications for this module. Note that test conditions,

unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)

livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen