Description
GE General Electric Technical Specifications: IS200ICBDH1B
IS200ICBDH1B Two independent two-wire RS485 ports are provided. Up to 32 489 relays can be daisy-chained together on a communica
tion channel without exceeding the driver capability. For larger systems, additional serial channels must be added. It is also
possible to use commercially available repeaters to increase the number of relays on a single channel to more than 32. A
suitable cable should have a characteristic impedance of 120 Ω (e.g. Belden #9841) and total wire length should not
exceed 4000 feet (approximately 1200 metres). Commercially available repeaters will allow for transmission distances
greater than 4000 ft.
Voltage differences between remote ends of the communication link are not uncommon. For this reason, surge protection
devices are internally installed across all RS485 terminals. Internally, an isolated power supply with an optocoupled data
interface is used to prevent noise coupling.
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200ICBDH1B | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
To ensure that all devices in a daisy-chain are at the same potential, it is imperative that the common termi
nals of each RS485 port are tied together and grounded only once, at the master. Failure to do so may
result in intermittent or failed communications.
The source computer/PLC/SCADA system should have similar transient protection devices installed, either internally or
externally, to ensure maximum reliability. Ground the shield at one point only, as shown below, to avoid ground loops.
Correct polarity is also essential. All IS200ICBDH1B must be wired with all ‘+’ terminals connected together, and all ‘–’ terminals con
nected together. Each relay must be daisy-chained to the next one. Avoid star or stub connected configurations. The last
device at each end of the daisy chain should be terminated with a 120 Ω ¼ W resistor in series with a 1 nF capacitor across
the ‘+’ and ‘–’ terminals. Observing these guidelines will result in a reliable communication system that is immune to system
transients.
It may be required to test for dielectric strength (“flash” or hi-pot”) with the 489 installed. The 489 is rated for 2000 V DC iso
lation between relay contacts, CT inputs, VT inputs, trip coil supervision, and the safety ground terminal G12. Some pre
cautions are required to prevent IS200ICBDH1B damage during these tests.
Filter networks and transient protection clamps are used between control power, trip coil supervision, and the filter ground
terminal G11. This filtering is intended to filter out high voltage transients, radio frequency interference (RFI), and electro
magnetic interference (EMI). The filter capacitors and transient suppressors could be damaged by application continuous
high voltage. Disconnect filter ground terminal G11 during testing of control power and trip coil supervision. CT inputs, VT
inputs, and output relays do not require any special precautions. Low voltage inputs (<30 V), RTDs, analog inputs, analog
outputs, digital inputs, and RS485 communication ports are not to be tested for dielectric strength under any circumstance
(see below)
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed
in a system are:
4 in a system using CPU Models 311, 313, or 323
8 in a system using CPU Model 331
32 in a system using CPU Models 340 and 341
64 in a system using CPU Models 350 – 364
Other Configuration Considerations
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load
requirements. The following table lists the specifications for this module. Note that test conditions,
unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen