Description
GE General Electric Technical Specifications: IS200ICCAH1ADB
The 489 is equipped with 3 independent serial communications ports supporting a subset of Modbus RTU protocol. The
front panel RS232 has a fixed baud rate of 9600 and a fixed IS200ICCAH1ADB data frame of 1 start/8 data/1stop/no parity. The front port is
intended for local use only and will respond regardless of the slave address programmed. The front panel RS232 program
port may be connected to a personal computer running the 489PC software. This program may be used for downloading
and uploading setpoint files, viewing measured parameters, and upgrading the 489 firmware to the latest revision.
For RS485 communications, each IS200ICCAH1ADB must have a unique address from 1 to 254. Address 0 is the broadcast address
which all relays listen to. Addresses do not have to be IS200ICCAH1ADB sequential but no two units can have the same address or conflicts
resulting in errors will occur. Generally each unit added to the link will use the next higher address starting at 1. Baud rates
can be selected as 300, 1200, 2400, 4800, 9600, or 19200. The data frame is fixed at 1 start, 8 data, and 1 stop bits, while
parity is optional. The computer RS485 port is a general purpose port for connection to a DCS, PLC, or PC. The Auxiliary
RS485 port may also be used as another general purpose port or it may be used to talk to Auxiliary GE Power Manage
ment Devices in the future.
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200ICCAH1ADB | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
For events that are recorded by the event recorder to be correctly time/date stamped, the correct time and date must be
entered. A battery backed internal clock runs IS200ICCAH1ADB continuously even when power is off. It has the same accuracy as an elec
tronic watch approximately ±1 minute per month. It must be periodically corrected either manually through the front panel or
via the clock update command over the RS485 serial link. If the approximate time an event occurred without synchroniza
tion to other relays is sufficient, then entry of time/date from the front panel keys is adequate.
If the RS485 serial communication link is used then all the relays can keep time in synchronization with each other. A new
clock time is pre-loaded into the memory map via the RS485 communications port by a remote computer to each relay con
nected on the communications channel. The computer IS200ICCAH1ADB broadcasts (address 0) a “set clock” command to all relays. Then all
relays in the system begin timing at the exact same instant. There can be up to 100 ms of delay in receiving serial com
mands so the clock time in each relay is ±100 ms, ± the absolute clock accuracy in the PLC or PC. See the chapter on
Communications for information on programming the time preload and synchronizing commands.
An IRIG-B signal receiver may be connected to 489 units with hardware revision G or higher. The relay will continuously
decode the time signal and set its internal time correspondingly. The “signal type” setpoint must be set to match the signal
provided by the receiver.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
The maximum number of 8-Channel Analog Current/Voltage Output modules that can be installed
in a system are:
4 in a system using CPU Models 311, 313, or 323
8 in a system using CPU Model 331
32 in a system using CPU Models 340 and 341
64 in a system using CPU Models 350 – 364
Other Configuration Considerations
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
Refer to Chapter 1 in this manual for details on power supply, baseplate, and module load
requirements. The following table lists the specifications for this module. Note that test conditions,
unless otherwise noted, are: VUSER = 24 VDC at an ambient temperature of 25 C (77 F)
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen