GE IS200IGDMH1BCB universal circuit board

Product name:
GE IS200IGDMH1BCB universal circuit board

Product model: IS200IGDMH1BCB

Quantity: inventory

Part No./PN: IS200IGDMH1BCB

Warranty: We provide warranty service for IS200IGDMH1BCB

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

GE General Electric Technical Specifications: IS200IGDMH1BCB

Generation IS200IGDMH1BCB of power will be displayed on the IS200IGDMH1BCB as positive watts. By convention, an induction generator normally requires

reactive power from the system for excitation. This is displayed on the IS200IGDMH1BCB as negative vars. A synchronous generator on

the other hand has its own source of excitation and can be operated with either lagging or leading power factor. This is dis

played on the 489 as positive vars and negative vars, respectively. All power quantities are measured from the phase

phase voltage and the currents measured at the output CTs.

 

brand Product Name Product model Order No
GE Fanuc Module card IS200IGDMH1BCB nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

In a motor/generator application, it may be desirable not to trip or alarm on reactive power until the machine is online and

the IS200IGDMH1BCB field has been applied. Therefore, this feature can be blocked until the machine is online and adequate time has expired

during which the field had been applied. From that point forward, the reactive power trip and alarm elements will be active.

A value of zero for the block time indicates that the reactive power protection is active as soon as both current and voltage

are measured regardless of whether the generator is online or offline. Once the 3-phase total reactive power exceeds the

positive or negative level, for the specified delay, a trip or alarm will occur indicating a positive or negative Mvar condition.

The level is programmed in per unit of generator rated Mvar calculated from the rated MVA and rated power factor. The

reactive power elements can be used to detect loss of excitation. If the VT type is selected as “None” or VT fuse loss is

detected, the reactive power protection is disabled. Rated Mvars for the system can be calculated as follows:

For example, given Rated MVA = 100 MVA and Rated Power Factor = 0.85, we have

If enabled, once the magnitude of 3-phase total power exceeds the Pickup Level in the reverse direction (negative MW) for

a period of time specified by the Delay, a trip or alarm will occur. The level is programmed in per unit of generator rated MW

calculated from the rated MVA and rated power factor. If the generator is accelerated from the power system rather than the

prime mover, the reverse power element may be blocked from start for a specified period of time. A value of zero for the

block time indicates that the reverse power protection is active as soon as both current and voltage are measured regard

less of whether the generator is online or offline. If the VT type is selected as “None” or VT fuse loss is detected, the

reverse power protection is disabled.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de

livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen