GE General Electric Technical Specifications: IS200IIDAG1ABB
Once the IS200IIDAG1ABB thermal model is setup, an alarm and/or trip element can be enabled. If the generator has been offline for a long
period of time, it will be at ambient temperature and thermal capacity used should be zero. If the generator is in overload,
once the thermal capacity used reaches 100%, a trip will occur. The IS200IIDAG1ABB thermal model trip will remain active until a lockout time
has expired. The lockout time will be based on the reduction of thermal capacity from 100% used to 15% used. This reduc
tion will occur at a rate defined by the stopped cooling time constant. The thermal capacity used alarm may be used as a
warning indication of an impending overload trip
brand | Product Name | Product model | Order No |
GE Fanuc | Module card | IS200IIDAG1ABB | nothing |
Place of Origin | Marketable land | Imported or not | defects liability period |
Europe and America | Nationwide and overseas | yes | a year |
Place of shipment | Delivery method | How to use | Applicable industries |
Xiamen | Shunfeng Express | Commissioning and installation | Power Plant Steel Plant Cement Plant Shipboard Papermaking |
Service advantages | Foreign import, goods preparation and supply | Reasonable price and reliable quality | Pictures are for reference only |
Product features | Primary source of goods, supply by model | After sales guarantee | Chen 1810693-7731 |
The IS200IIDAG1ABB has four analog output channels (4 to 20 mA or 0 to 1 mA as ordered). Each channel may be individually config
ured to represent a number of different measured parameters as shown in the table below. The minimum value pro
grammed represents the 4 mA output. The maximum value programmed represents the 20 mA output. All four of the
outputs are updated once every 50 ms. Each parameter may only be used once.
The analog output parameter may be chosen as Real Power (MW) for a 4 to 20 mA output. If rated power is 100 MW, the
minimum is set for 0.00 × Rated, and the maximum is set for 1.00 × Rated, the analog output channel will output 4 mA
when the real power measurement is 0 MW. When the IS200IIDAG1ABB real power measurement is 50 MW, the analog output channel will
output 12 mA. When the real power measurement is 100 MW, the analog output channel will output 20 mA.
There are 4 analog inputs (4 to 20 mA, 0 to 20 mA, or 0 to 1 mA) that may be used to monitor transducers such as vibration
monitors, tachometers, pressure transducers, etc. These inputs may be used for alarm and/or tripping purposes. The
inputs are sampled every 50 ms. The level of the analog input is also available over the communications port. With the
489PC program, the level of the transducer may be trended and graphed.
Before the input may be used, it must be configured. A name may be assigned for the input, units may be assigned, and a
minimum and maxi-mum value must be assigned. Also, the trip and alarm features may be blocked until the generator is
online for a specified time delay. If the block time is 0 seconds, there is no block and the trip and alarm features will be
active when the generator is offline or online. If a time is programmed other than 0 seconds, the feature will be disabled
when the generator is offline and also from the time the machine is placed online until the time entered expires. Once the
input is setup, both the trip and alarm features may be configured. In addition to programming a level and time delay, the
PICKUP setpoint may be used to dictate whether the feature picks up when the measured value is over or under the level.
If a vibration transducer is to be used, program the name as “Vibration Monitor”, the units as “mm/s”, the minimum as “0”,
the maximum as “25”, and the Block From Online as “0 s”. Set the alarm for a reasonable level slightly higher than the nor
mal vibration level. Program a delay of “3 s” and the pickup as “Over”.
Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the de
livery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!
Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen