HIMA digital module F7553 Z7306 Ethernet communication module

Product name:HIMA digital module F7553 Z7306 Ethernet communication module

Product model:Z7306

Quantity: inventory

Warranty: We provide warranty service for Z7306

Shipping Port:FuJian

Product technical documents: no relevant documents

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Z7306 Personnel configuring the HIQuad X hardware must observe the following product-dependent

safety requirements.

Only devices with electrically protective separation from the power supply may be connected

to the system

Only safety-related modules may be used to Z7306 process safety-related tasks.

The conditions of use detailed in the system manual, particularly those concerning supply

voltage and climate, must be observed.

Power must be supplied by power supply units Z7306 complying with SELV and PELV. For the

power supply units, the following applies:

24 VDC power supply: The voltage of the power supply units may not exceed 31 V.

48 VDC power supply: The voltage of the power supply units may not exceed 62 V.

The requirements for power supply provided through the mains supply are the same as

those applying to power supply units.

 

brand Product Name Product model Order No
HIMA modular Z7306 nothing
Place of Origin Marketable land Imported or not defects liability period
Europe and America Nationwide and overseas yes a year
Place of shipment Delivery method How to use Applicable industries
Xiamen Shunfeng Express Commissioning and installation Power Plant Steel Plant Cement Plant Shipboard Papermaking
Service advantages Foreign import, goods preparation and supply Reasonable price and reliable quality Pictures are for reference only
Product features Primary source of goods, supply by model After sales guarantee Chen 1810693-7731

 

Z7306 Product-Independent Programming Requirements

Personnel developing user programs must observe the following product-independent safety

requirements:

In safety-relevant applications, ensure that the safety-relevant system parameters are

properly configured.

In particular, this applies to the system configuration, maximum cycle time and safety time.

3.4.4

Product-Dependent Programming Requirements

The SILworX programming tool must be used for programming the HIQuad X system. The

following requirements for using SILworX must be met.

The application described in the specification must be validated, verified and its proper

implementation must be documented. Z7306 A complete test of the logic must be performed by

trial.

If the user program is changed, all the logic parts affected by the changes must be tested.

A system response to faults must be defined for faults in safety-related input and output

modules in accordance with the application-specific safety-related requirements. These are

for instance fault responses in the user program and the configuration of safe initial values

for variables.

3.4.5

Z7306 Communication

The following requirements for communication of data and to systems must be met.

When implementing safety-related communications between various systems, ensure that

the overall response time of the system does not exceed the worst case response time

permitted for safeethernet or HIPRO-S V2. All calculations must be performed in

accordance with the rules given in Chapter 11.3.

During the transfer of (safety-relevant) data, IT security rules must be observed.

The transfer of safety-relevant data through public or Z7306 publicly accessible networks (e.g., the

Internet, WLAN) is only permitted if additional security measures have been implemented,

e.g., a VPN tunnel and firewall.

If data is transferred through company/plant internal networks, administrative and technical

measures must be implemented to ensure sufficient protection against manipulation (e.g., a

firewall to separate the safety-relevant components of the network from other networks).

Never use the standard protocols to transfer safety-related data.

The communication interfaces must be connected to devices with electrically protective

separation.

Why are the prices of many products of our company more competitive?
(1) Source purchase to reduce the price difference in the intermediate phase
(2) Stable channel and more guaranteed supply
Lead time problem
(1) For the spot products in stock, the delivery can be arranged on the same day after the contract payment is signed
(2) Order products and deliver according to the quoted delivery date
Xiamen Xiongba adheres to the enterprise philosophy of “improving the value of spare parts supply chain”,
For the simple purchase procedure of spare parts, ensure that they are delivered to the site in a timely manner, and help users reduce the risk of downtime caused by the shortage of spare parts
The emergency spare parts support service is complete, and the user can customize the spare parts. The quality of the spare parts is reliable. All the spare parts provided enjoy a one-year super long warranty
Spot stock, fast response, reduce user capital investment, improve spare parts utilization, spare parts replacement!

 

Details: If you need urgent delivery orders, please feel free to contact us, and we will try our best to meet your needs.
Price problem: If you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.
Contact us:+86 181 0693 7731
Mail: 2872270648@qq.com
Contact: Chen