HONEYWELL SDOL-0424 24 VDC output module

¥1,100.00

Description: PLC/DCS IO MODULE

Quantity: inventory

Warranty: We provide warranty service for SDOL-0424

FC-TSDOL-0424C Fault Protection Digital Output FTA, Current Limiting (24 Vdc, 4-channel)

80 in stock

Category: SKU: SDOL-0424
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

If the SDOL-0424 input signal is identified as inconsistent through comparison, the system will switch to the safe state of the affected input and indicate this through the system flag. The fault response “system shutdown, process group shutdown, or alarm” should be programmed.

10213/1/1 and 10213/2/1 and FC-SDO-04110
4 channel digital output module 110 VDC
10213/1/2 and 10213/2/2 4 channel digital output module 60 VDC
10213/1/3 and 10213/2/3 and FC-SDO-0448
4 channel digital output module 48 VDC
10214/1/2 3 channel digital output module 220 VDC
10215/1/1 and 10215/2/1and FC-SDO-0424
4 channel digital output module 24 VDC
10216/1/1 and 10216/2/1and FC-SDOL-0424
4 channel digital output module 24 VDC with loop-monitoring
10216/2/3 andFC-SDOL-0448
4 channel digital output module 48 VDC with loop-monitoring
10302/1/1 and 10302/2/1 Watchdog repeater
10305/1/1 16 channel analog input converter
10311/2/1 Dual key switch module

FTA-T-02 Fail-safe digital output FTA (24/48/60 VDC, 24 channels)
FC-TSDO-0824 Fail-safe digital output FTA (24 Vdc, 8 channels)
FC-TSAI-0410 Fail-safe analog input FTA (4 channels)
FC-TSHART-1620m Fail-safe 0(4)-20 mA analog input FTA with HART interface
(16 channels)
FC-TSAO-0220m Fail-safe analog output FTA (0(4)-20 mA, 2 channels)
FTA-T-05 Fail-safe digital output FTA (24 VDC, 12 channels)
FC-TSDO-0424 Fail-safe digital output FTA (24 Vdc, 4 channels)
FTA-T-06 115 / 230 VAC digital input FTA Fail-Safe (potential free input contacts)

Faults in redundant central parts which are detected and localised by the self-tests result in single-central part operation for a limited time period. The mode of operation; single or redundant does not influence the coverage of the self-tests. The self-test interval is not extended for singlecentral part operation. The self-test interval shall be less than the fault tolerance period of the process (PST). The fail-to-danger-rate of an application including sensors and positioners at the controller’s ascertained MTBF figures and fault coverage rates are not significantly increased by single-channel operation for a limited period.

This period has to be defined by the manufacturers PFD calculation for a specific system The calculated maximum duration for single-central part operation depends on the specific process concerned and must be specified individually for each application. On the FSC system, this is specified by means of the system parameter “Interval time between faults”.