ICSI16E1 ABB distributed control system industrial DCS module card

Numer modelu: ICSI16E1

Manufacturer: ABB
Quantity:ten
Serial ports: 7
Network ports: 6
Port isolation: 180 VDC
Weight : 2Kg
Shipping Weight : 3 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number ICSI16E1
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

The drive automatically estimates motor characteristics using Standstill ID run when
the drive is started for the first time in vector control and after any motor parameter
(group 99 Motor data) is changed. This is valid when
• parameter 99.13 ID run requested selection is Standstill and
• parameter 99.04 Motor control mode selection is Vector.
In most applications there is no need to perform a separate ID run. The ID run should
be selected manually if:
• vector control mode is used (parameter 99.04 Motor control mode is set to
Vector), and
• permanent magnet motor (PM) is used (parameter 99.03 Motor type is set to
Permanent magnet motor), or
• synchronous reluctance motor (SynRM) is used (parameter 99.03 Motor type is
set to SynRM), or
• drive operates near zero speed references, or
• operation at torque range above the motor nominal torque, over a wide speed
range is needed.
Do the ID run with the ID run assistant by selecting Menu > Primary settings >
Motor > ID run (see page 39) or with parameter 99.13 ID run requested (see page
43).
Note: If motor parameters (99 Motor data) are changed after the ID run, it must be
repeated.
Note: If you have already parameterized your application using the scalar motor
control mode (99.04 Motor control mode is set to Scalar) and you need to change
motor control mode to Vector,
• change the control mode to vector with the Control mode assistant (go to Menu
> Primary settings > Motor > Control mode) and follow the instructions. The ID
run assistant then guides you through the ID run.
or
• set parameter 99.04 Motor control mode to Vector, and
• for I/O controlled drive, check parameters in groups 22 Speed reference
selection, 23 Speed reference ramp, 12 Standard AI, 30 Limits and 46
Monitoring/scaling settings.