LXN1604-6 3BHL000986P7000 ABB Programmable Logic Controller for Distributed Control System

Numer modelu: LXN1604-6 3BHL000986P7000

Manufacturer: ABB
Quantity:ten
Serial ports: 7
Network ports: 6
Port isolation: 180 VDC
Weight : 2Kg
Shipping Weight : 3 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number LXN1604-6 3BHL000986P7000
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

01.23 AO2 [mA] Value of analog output AO2. 1 = 0.001 mA
01.24 ACTUAL VALUE 1 Feedback signal of process PID controller. Only when the parameter 99.02=PD CTRL
Is constantly refreshed.
0 = 0% 10000
= 100%
01.25 Feedback signal of ACTUAL VALUE 2 process PID controller. Only when parameter 99.02=PID CTRL
Is constantly refreshed.
0 = 0% 10000
= 100%
01.26 Deviation of the PID controller of the CONTROL DEVIATION process, that is, the difference between the given value and the actual value. Only when the parameter
99.02=PID CTRL will be refreshed continuously.
-10000 = –
100% 10000 =
100%
01.27 The current application macro of APPLICATION MACRO (corresponding to the value of parameter 99.02). See 99.02
01.28 EXT AO1 [mA] Analog I/O expansion module output value 1 (optional). 1 = 0.001 mA
01.29 EXT AO2 [mA] Analog I/O expansion module output value 2 (optional). 1 = 0.001 mA
01.30 The maximum temperature value of radiator detected by PP 1 TEMP in inverter 1. 1 = 1 °C
01.31 The maximum temperature value of radiator detected by PP 2 TEMP in inverter 2 (only used for high-power inverter
Yuan).
1 = 1 °C
01.32 The maximum temperature value of the radiator detected by PP 3 TEMP in inverter 3 (only used for high-power inverter in parallel
Yuan).
1 = 1 °C
01.33 The maximum temperature value of the radiator detected by PP 4 TEMP in inverter 4 (only used for high-power inverter in parallel
Yuan).
1 = 1 °C
01.34 ACTUAL VALUE Process PID controller actual value. See parameter 40.06. 0 = 0% 10000
= 100%
01.35 MOTOR 1 TEMP measured temperature. See parameter 35.01. 1 = 1°C/ohm
01.36 Motor 2 TEMP measured temperature. See parameter 35.04. 1 = 1°C/ohm
01.37 MOTOR TEMP EST motor temperature estimate. The power off signal value is saved. 1 = 1 °C
01.38 AI5 [mA] The value of the analog input signal AI5 read from the analog I/O expansion module (optional) AI1. Voltage signal
The number can also be displayed in mA (instead of V).
1 = 0.001 mA
01.39 AI6 [mA] The value of the analog input signal AI6 read from the analog I/O expansion module (optional) AI2. Voltage
The signal can also be displayed in mA (instead of V).
1 = 0.001 mA
01.40 DI7-12 STATUS Status of digital inputs DI7 to DI12 read from the digital I/O expansion module (optional). for example
The value 00000 1: DI7 is on, and DI8~DI12 is off.
1 = 1
01.41 Status of EXT RO STATUS digital I/O expansion module relay output (optional). Example value 0000001: module
RO1 of 1 is powered on. The outputs of other relays are de energized.
1 = 1
01.42 The percentage of the actual speed of the PROCESS SPEED REL motor to the maximum absolute speed.
If parameter 99.04 is SCALAR, the value is the corresponding actual output frequency.
1 = 1
01.43 MOTOR RUN TIME counter. When the inverter is modulated, the counter operates. Parameters can be used
34.06 Reset.
1 = 10 h
01.44 Running time of FAN ON-TIME drive unit cooling fan.
Note: The counter can be reset using the DriveWindow PC tool. It is recommended to replace the wind
Reset when the fan is turned on.
1 = 10 h
01.45 CTRL BOARD TEMP control panel temperature. 1 = 1°C
01.46 SAVED KWH saves energy compared with direct power frequency power supply motor. 1 = 100kWH
01.47 SAVED GWH saves energy compared with direct power frequency power supply motor. 1 = 1GWH
01.48 SAVED AMOUNT saves cost by comparing with direct power frequency power supply motor, parameter 01.46x parameter 45.02. 1 = 100 cur
01.49 SAVED AMOUNT M saves cost compared with direct power frequency power supply motor. 1 = 1 Mcur
01.50 SAVED CO2 reduces CO2 emission by kg compared with direct power frequency power supply motor. Energy saving MWHx500. 1 = 100kg
01.51 SAVED CO2 KTON reduces CO2 emission, kton compared with direct power frequency power supply motor. 1 = 1kton