MB510 3BSE002540R1 ABB Programmable Logic Controller for Distributed Control System

Numer modelu: MB510 3BSE002540R1

Manufacturer: ABB
Quantity:ten
Serial ports: 7
Network ports: 6
Port isolation: 180 VDC
Weight : 2Kg
Shipping Weight : 3 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number MB510 3BSE002540R1
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

03.25 Fieldbus code of the last warning of LATEST WARNING.
03.26 2. Fieldbus code of the last but not the last warning of LATEST WARNING.
03.27 3. Fieldbus code of the last but not the last warning of LATEST WARNING.
03.28 4. Fieldbus code of the fourth last warning of LATEST WARNING.
03.29 5. Fieldbus code of the fifth last warning of LATEST WARNING.
03.30 LIMIT WORD INV A 16 bit data word. See “3.30 INV Limiting Words” on page 217.
03.31 ALARM WORD 6 A 16 bit data word. See “3.31 Alarm word 6” on page 217.
03.32 Status of EXT IO STATUS emergency stop and sine wave filter digital port expansion module. See EXT on page 218
IO STATUS。
03.33 FAULT WORD 6 A 16 bit data word. See “3.33 Fault Word 6” on page 217.
04 ACTUAL SIGNALS paralleling module information 2)
04.01 FAULT INT INFO A 16 bit data word. See 04.01 FAULT INT INFO on page 219.
04.02 INT SC INFO is a 16 bit data word. See 04.02 INT SC information on page 220.
09 ACTUAL SIGNALS Adaptive Program signal
09.01 AI1 The analog input AI1 value of SCALED after proportional conversion and rounding. 20000 = 10 V
09.02 The analog input AI2 value of AI2 SCALED after proportional conversion and rounding. 20000 = 20
mA
09.03 The analog input AI3 value of AI3 SCALED after proportional conversion and rounding. 20000 = 20
mA
09.04 The analog input AI5 value of AI5 SCALED after proportional conversion and rounding. 20000 = 20
mA
09.05 The analog input AI6 value of AI6 SCALED after proportional conversion and rounding. 20000 = 20
mA
09.06 The control word (CW) of the main given data set received by the DS MCW from the master workstation through the fieldbus interface. 0… 65535 (ten
Base)
09.07 Master REF1 is the set value 1 (REF1) of the master given data set received from the master workstation through the field bus interface- 32768 …
thirty-two thousand seven hundred and sixty-seven
09.08 Master REF2 is the set value 2 (REF2) of the master given data set received from the master workstation through the fieldbus interface- 32768 …
thirty-two thousand seven hundred and sixty-seven
09.09 AUX DS VAL1 receives auxiliary data set value 1 from the master workstation through the field bus interface- 32768 …
thirty-two thousand seven hundred and sixty-seven
09.10 AUX DS VAL2 receives auxiliary data set value 2 from the master station through the field bus interface- 32768 …
thirty-two thousand seven hundred and sixty-seven
09.11 AUX DS VAL3 receives auxiliary data set value 3 from the master station through the field bus interface- 32768 …
thirty-two thousand seven hundred and sixty-seven
09.12 LCU ACT SIGNAL1 selects the grid side converter signal through parameter 95.08. A 16 bit data word.
09.13 LCU ACT SIGNAL2 selects the grid side converter signal through parameter 95.09. A 16 bit data word.