EXT1 STRT/STP/DIR defines the connection and signal source of external control ground 1 (EXT1) for starting, stopping and steering commands.
NOT SEL has no external start, stop and turn command signal source. one
DI1 controls start and stop by digitally entering DI1 values, where 0=stop and 1=start. Steering pick-up
Depends on the definition of parameter 10.3 DIRECTION.
Warning! After fault reset, if the start signal is still valid, the drive unit will restart
Move.
two
DI1,2 controls start and stop by digitally entering DI1 values, where 0=stop and 1=start. Number of passes
Input the value of DI2 to control the steering, where 0=forward rotation and 1=reverse rotation. To control steering, parameters
10.03 DIRECTION must also be set to REQUEST.
Warning! After fault reset, if the start signal is still displayed, the transmission unit will restart
Move.
three
DI1P and 2P are started by inputting pulse to digital DI1. When the value is 0 ->1, they are started. By giving digital input
DI2 input pulse to stop, its value is 1 ->0, stop. Steering depends on parameter 10.03 DIRECTION
Definition of.
four
DI1P, 2P and 3 are started by inputting pulse to digital input DI1, and their values are 0 ->1. By giving digital input
Enter DI2 input pulse to stop, and stop when its value is 1 ->0. Control by digital input of DI3 value
Steering, where 0=forward rotation and 1=reverse rotation. If the steering is to be controlled, parameter 10.03 DIRECTION
Must be set to REQUEST.
five
DI1P, 2P and 3P start in the positive direction by inputting DI1 pulse to the digital input. When its value is 0 ->1, it starts in the positive direction
Move. Carry out reverse startup by inputting pulse to digital input DI2. When its value is 0 ->0, reverse startup
Move. Stop the machine by giving the input pulse of digital input DI3, when its value is 1 ->”0″. If
To control steering, parameter 10.03 DIRECTION must be set to REQUEST.
six
DI6 See option DI1. seven
DI6,5 See options DI1,2, DI6: start/stop, DI5: direction. eight
KEYPAD wheel. To control steering, parameter 10.03 DIRECTION must be set to REQUEST. nine
COMM.CW field bus control word. ten
DI7 See option DI1. eleven
DI7,8 See option DI1,2. DI7: start/stop, DI8: direction. twelve
DI7P, 8P See options DI1P, 2P. thirteen
DI7P, 8P, 9 See options DI1P, 2P, 3. fourteen
DI7P, 8P, 9P See options DI1P, 2P, 3P. fifteen
PARAM 10.04 Parameter 10.04 Selected signal source. sixteen
DI1 F DI2 R sends start, stop and steering commands through digital inputs DI1 and DI2.
Note: Parameter 10.03 DIRECTION must be set to REQUEST.
seventeen
10.02 EXT2 STRT/STP/DIR defines the connection and signal source of external control ground 2 (EXT2) for starting, stopping and steering commands.
NOT SEL See parameter 10.01. one
DI1 See parameter 10.01.