MVR 0.44-10KA ABB Programmable Logic Controller for Distributed Control System

Numer modelu: MVR 0.44-10KA

Manufacturer: ABB
Quantity:ten
Serial ports: 2
Network ports: 9
Port isolation: 120 VDC
Weight : 3Kg
Shipping Weight : 4 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number MVR 0.44-10KA
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

See parameter 11.03 for AI5 * AI6. thirty-two
MIN (AI5,6) See parameter 11.03. thirty-three
MAX (AI5,6) see parameter 11.03. thirty-four
DI11U, 12D (R) See parameter 11.03. thirty-five
See parameter 11.03 for DI11U and 12D. thirty-six
PARAM 11.11 Signal source selected by parameter 11.11. thirty-seven
AI1 BIPOLAR See parameter 11.03. thirty-eight
11.07 EXT REF2 MINIMUM defines the minimum value (absolute value) of externally given REF2.
It is equivalent to the minimum setting of the signal source used.
0… 100% setting range (100%), equivalent to signal source range value:
-The signal source is an analog input: see the example in parameter 11.04.
-The signal source is a serial communication link: see the chapter Fieldbus Control.
0 … 10000
11.08 EXT REF2 MAXIMUM defines the maximum value (absolute value) of externally given REF2.
It is equivalent to the maximum setting value of the signal source used.
0… 600% setting range (100%), equivalent to signal source range value:
-The signal source is an analog input: see parameter 11.04.
-The signal source is a serial communication link: see the chapter Fieldbus Control.
0 … 6000
11.09 EXT 1/2 SEL PTR defines the variable or constant of PAR 11.09 option in parameter 11.02.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter pointer or a constant value. See the description in parameter 10.04-
11.10 EXT 1 REF PTR defines the variable or constant of PAR 11.10 option in parameter 11.03.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter pointer or a constant value. See the description in parameter 10.04-
11.11 EXT 2 REF PTR defines the variable or constant of PAR 11.11 option in parameter 11.06.
-255.255.31 …
+255.255.31 / C.-
32768 … C.32767
Parameter pointer or a constant value. See the description in parameter 10.04-
12 Selection and value of CONSTANT SPEED. The current constant speed value takes precedence over the speed setting value of the drive unit. See 57
The constant speed of the page.
Note: If SCALAR is selected for parameter 99.04, only constant speed 1~5 and constant speed 15 are available.
12.01 CONST SPEED SEL activates the constant speed option, or selects the activation signal.
NOT SEL is not used at constant speed. one
DI1 (SPEED1) digital input DI1 activates the speed defined by parameter 12.02, where 1=valid and 0=invalid. two
DI2 (SPEED2) digital input DI2 activates the speed defined by parameter 12.03, where 1=valid and 0=invalid. three
DI3 (SPEED3) digital input DI3 activates the speed defined by parameter 12.04, where 1=valid and 0=invalid. four
DI4 (SPEED4) digital input DI4 activates the speed defined by parameter 12.05, where 1=valid and 0=invalid. five
DI5 (SPEED5) digital input DI5 activates the speed defined by parameter 12.06, where 1=valid and 0=invalid. six
DI6 (SPEED6) digital input DI6 activates the speed defined by parameter 12.07, where 1=valid and 0=invalid. seven