NI PCI/PXI-6052E Multi functional Analog Digital Equipment

¥5,900.00

– NI PCI-6052E
– NI PXI-6052E
– DAQPad-6052E

Category: SKU: PXI-6052E Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

NI PCI/PXI-6052E Multi functional Analog Digital Equipment

 

You can install the NI PCI/PXI-6052E in any available PCI system or 5 V PXI slot, respectively, in the computer. However, to achieve best noise performance, leave as much room as possible between the NI PCI/PXI-6052E and other devices. You can connect the DAQPad-6052E to any available 1394 port. The following are general installation instructions. Consult the computer or chassis user manual or technical reference manual for specific instructions and warnings about installing new devices.

NI PXI-6052E

1. Power off and unplug the computer.

2. Choose an unused PXI slot in the system. For maximum performance, the NI PXI-6052E has an onboard DMA controller, but you can only use this controller if the device is installed in a slot that supports bus arbitration or bus master cards. NI recommends installing the NI PXI-6052E in such a slot. The PXI specification requires all slots to support bus master cards, but the CompactPCI specification does not. If you install the device in a CompactPCI non-master slot, disable the NI PXI-6052E onboard DMA controller using the ADE.

3. Remove the filler panel for the slot that you chose.

4. Insert the NI PXI-6052E into a 5 V PXI slot. Use the injector/ejector handle to fully insert the device into the chassis.

5. Screw the front panel of the NI PXI-6052E to the front panel mounting rail of the system. 6. Plug in and power on the computer.

The NI PXI-6052E is now installed.

 

NI PCI/PXI-6052E

The NI PCI/PXI-6052E is completely software configurable. You must perform two types of configuration on the NI PCI/PXI-6052E—bus-related and data acquisition-related configuration. The NI PCI/PXI-6052E is fully compatible with the industry-standard PCI Local Bus Specification, Revision 2.2, and PXI Specification, Revision 2.0.

This compatibility allows the PCI or PXI system to automatically perform all bus-related configurations, including setting the device base memory address and interrupt channel. You can modify data acquisition-related configuration settings such as AI polarity, range, and mode through application-level software, such as NI-DAQ, LabVIEW, and Measurement Studio.

 

Number of channels
PCI/PXI-6052E,
DAQPad-6052E ………………………… 16 single-ended or 8 differential
(software-selectable)
Type of ADC…………………………………… Successive approximation
Resolution ………………………………………. 16 bits, 1 in 65,536
Max sampling rate……………………………. 333 kS/s guaranteed