NI PXI-4065 PXI Digital Multimeter

¥5,900.00

PXI-4065 DC System Speed Characteristics
Range or function changes 10/s
Auto Range time, DC V 200 ms
Auto Range time, DC I 200 ms
Auto Range time, resistance 250 ms
Trigger latency <1 μs
Maximum trigger rate 2.5 kHz

Category: SKU: PXI-4065 Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Title: Environmental Specifications and Compliance for the PXI-4065

Introduction: Understanding the storage conditions and compliance standards for the PXI-4065 is crucial for ensuring optimal performance and longevity. This article outlines the environmental specifications and compliance details, providing valuable insights for users.

Section 1: Storage Environment 1.1 Ambient Temperature Range: The PXI-4065 is designed to withstand a broad ambient temperature range from -40 °C to 70 °C. This specification has been rigorously tested in accordance with IEC 60068-2-1 and IEC 60068-2-2 standards.

1.2 Relative Humidity Range: In noncondensing environments, the relative humidity range for storage is 5% to 95%. This range has been tested and complies with IEC 60068-2-56 standards.

Section 2: Shock and Vibration Resistance 2.1 Operational Shock: The PXI-4065 can withstand operational shocks of 30 g peak, half-sine, with an 11 ms pulse. Testing has been conducted in accordance with IEC 60068-2-27, and the test profile aligns with MIL-PRF-28800F standards.

2.2 Random Vibration: For both operating and nonoperating conditions, the PXI-4065 exhibits resilience to random vibrations. Operating vibrations range from 5 Hz to 500 Hz, with 0.3 grms, tested according to IEC 60068-2-64 standards. Nonoperating vibrations range from 5 Hz to 500 Hz, with 2.4 grms, exceeding MIL-PRF-28800F, Class 3 requirements.

Section 3: Compliance and Certifications 3.1 Caution Regarding Usage: Users are cautioned against using the PXI-4065 in a manner not described in the provided documentation, as this can potentially impair the protection provided by the instrument.

3.2 Industrial Use and Electromagnetic Emissions: The PXI-4065 is intended for industrial locations. However, users should be aware that usage in residential areas may cause interference. Special measures must be taken to reduce electromagnetic emissions and prevent interference with radio and television broadcasts.

 

Conclusion: By adhering to the specified storage conditions and compliance guidelines, users can maximize the reliability and performance of the PXI-4065 in various environments. These details empower users to make informed decisions regarding the installation and use of this precision instrument.