P0961EF-CP30B Original FXOBORO Module

¥980.00

Product model: P0961EF-CP30B
Contact person: KELLY
Email: geabbdcs@gmail.com
Address: Innovation Center, No. 1733 Lvling Road, Siming District, Xiamen City

Category: SKU: P0961EF-CP30B Tag:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

In order to avoid electrical interference from other peripheral devices, programmable controllers should be kept as far away from high-voltage power lines and equipment as possible, and a distance of at least 200mm should be left between programmable controllers and high-voltage equipment and power lines. When the programmable controller is installed vertically, it is necessary to strictly prevent wire heads, iron filings, etc. from falling into the interior of the programmable controller from the ventilation window, causing a short circuit on the printed circuit board, making it unable to work properly or even permanently damaged.

Power Wiring The PLC power supply is 50Hz, 220V, and 10% AC. For example, the FX series programmable controller has a DC 24V output terminal. This terminal can provide DC 24V power supply for input sensing (such as photoelectric switches or proximity switches). If the power supply fails and the interruption time is less than 10ms, the PLC operation will not be affected. If the power interruption exceeds 10ms or the power decrease exceeds the allowable value, the PLC will stop working and all output points will be disconnected simultaneously. When the power is restored, if the RUN input is turned on, the operation will proceed automatically. The PLC itself has sufficient resistance to interference from the power cord. If the power interference is particularly severe, an isolation transformer with a ratio of 1:1 can be installed to reduce interference between the equipment and the ground.

Good grounding is an important condition to ensure the reliable operation of PLC, and can avoid accidental voltage surge hazards. The grounding wire is connected to the grounding terminal of the machine, and the basic unit is grounded. If an expansion unit is to be used, its grounding point should be connected to the grounding point of the basic unit. In order to suppress interference on the power supply, input, and output terminals, a dedicated ground wire should be connected to the programmable controller, and the grounding point should be separated from the grounding point of the power equipment (such as the motor). If this requirement cannot be met, it is also necessary to achieve common grounding with other equipment and prohibit series grounding with other equipment. The grounding point should be as close as possible to the PLC. When a passive contact input device is used for the 2.4 DC 24V terminal, the internal 24V power supply of the PLC provides a current of 7mA per point to the input through the input device. The 24V terminal on the PLC can also provide current to external sensors such as proximity switches or photoelectric switches.

When the 24V terminal is used as the sensor power supply, the COM terminal is the DC 24V ground terminal. If an extended crew member is used, the 24V terminals of the basic unit and the extended unit should be connected. Additionally, no external power supply can be connected to this terminal. If overload occurs, the voltage will automatically drop, and this input point will not have any effect on the programmable controller. The number of input points for each model of PLC is specified. For each unused input point, it does not consume power, so in this case, the ability of the 24V power supply terminal to provide external current can be increased. For example, the empty terminal of the FX series PLC cannot be used under any circumstances. 2.5 Input wiring PLC generally accepts switch signals from travel switches, limit switches, and other inputs. The input wiring terminal is the port for the load conversion signal between the PLC and external sensors. Input wiring generally refers to the wiring between external sensors and input ports.

 

4PP480.1505-B5
4PP420.1043-B5
4PP420.0571-45
4PP320.0571-35
4PP220.0571-45
4PP210.0000-95
4PP120.0571-21
4PP065-0571-P74
4PP035.0300-01
4D1164.00-090
4C2200.01-110
4B1260.00-K07
490NRP95400
490NRP25400
490NRP25300