PFEA111-20 3BSE050090R20 ABB Tension pillow type sensor unit vertical load cell

Numer modelu: PFEA111-20 3BSE050090R20

Manufacturer: ABB
Quantity:ten
Serial ports: 2
Network ports: 9
Port isolation: 120 VDC
Weight : 3Kg
Shipping Weight : 4 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number PFEA111-20 3BSE050090R20
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

The measuring equipment can be divided into four parts:
• The mechanical installation.
• The load cell.
• The junction boxes and the cabling.
• The control unit (see the control unit manual).
The fault symptoms indicate in which part the fault lies.
• Faults in the mechanical installation often result in an unstable zero point or incorrect sensitivity.
If a fault follows something else in the process, such as temperature, or can be linked
to a particular operation, it probably originates from something in the mechanical installation.
• Load cells are extremely robust and can withstand five times their nominal load in the measuring direction. If a load cell has nevertheless been so overloaded that its data have been
altered, this is probably due to an event in the mill, such as web/strip breakage. On excessive overload the first thing that happens is that the zero point shifts.
• Problems such as interference or unstable zero point may be caused by wiring faults. Some
malfunctions may be due to the proximity of cables that cause interference. Incorrect installation, such as imbalance in a cable or screens earthed at more than one end may cause the
zero point to become unstable. Cables are subject to mechanical wear, and should be
checked regularly. The junction box should also be checked, especially if it is subject to
vibration.
• A fault in the control unit usually causes intermittent loss of a function. It is unusual for the
control unit to cause stability problems. Faults in connected units may affect the operation of
the control unit. For further details see the control unit manual.