PFEA113-65 ABB Tension pillow type sensor unit vertical load cell

Numer modelu: PFEA113-65

Manufacturer: ABB
Quantity:ten
Serial ports: 2
Network ports: 9
Port isolation: 120 VDC
Weight : 3Kg
Shipping Weight : 4 Kg

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

Manufacturer ABB
Brand ABB
Series module
Part Number PFEA113-65
Product Type module
Quality 100% New Original
Stock In stock
Delivery time 1-3 days after Payment
After-sales Service Have
Warranty 1 year
Shipping term DHL / FEDEX/ EMS /UPS/TNT/EMS

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.

 

Load Division
Load Division is the resolution that will be used on Profibus. The Load Division value is
calculated by PFEA112 and depends on the set measuring range.
The measuring range is divided into a limited number of divisions in the range 2001 – 5000.
The Load Division value = one division, contains only one significant digit (1, 2 or 5).
The Profibus can handle max. –32768 to +32767 (216) divisions.
Example 1:
a. Profibus Measuring Range (set by user) = 15 500 N
(estimated web tension during normal operation)
b. Load Division calculated by PFEA112 = 5 N
(value of least significant bit on Profibus)
c. Profibus Measuring Range/Load Division = 15500/5 = 3100
(the measuring range is divided into 3100 divisions)
Example 2:
If the Load Division, 5 N, in Example 1 is not sufficient, the Load Division can be adjusted.
This can be done by setting (decreasing) MeasuringRange in the Miscellaneous Menu to a
value that gives a sufficient Load Division (resolution).
a. Measuring Range = 9000 N
(New, lower setting on measuring range)
b. New Load Division calculated by PFEA112 = 2 N
(New value of least significant bit on Profibus)
With the setting 9000 N in PFEA112 , the Profibus measuring range 0 – 15500 N (divided into
7750 divisions) can still be used, now with the Load Division (resolution) 2 N.
Normally, there is no need to set the measuring range lower than 1/3 of the estimated web
tension during normal operation.
The max. value that can be transmitted via Profibus, for a given Load Division, is:
– Max. value = Load Division x 32767