UFC718AE01 HIEE300936R0001 ABB DCS rack power module

Digital model: UFC718AE01 HIEE300936R0001
Manufacturer: ABB
Weight: 1Kg
Shipping weight: 2Kg
Quantity: 8
Warranty:1 year
Imported: Yes
Available for sale: nationwide
Shipping term:DHL / FEDEX/ EMS /UPS/TNT/EMS

Category:
Whatsapp:+86 15359293870
WeChat:+86 18106937731
                E-mail:geabbdcs@gmail.com
Contacts:kelly CHEN

Description

UFC718AE01 Operation Details
1. Obtain the size of cross loading data. The REDUNDANCY object can be read using the Get System Value (GSV) command.
See the Logix5000 Controller General Instruction Reference Manual (Publication No. 1756-RM003),
Learn more about GSV directives and SSV directives.
2. Estimate cross loading time. Which controller do you have?
·If ControlLogix5555, cross loading time=(0.0015 ms * DINT)+1
Ms Housekeeping time
·If ControlLogix5561, cross loading time=(0.0013 ms * DINT)+1
Ms Housekeeping time
·If ControlLogix5562, cross loading time=(0.0013 ms * DINT)+1
Ms Housekeeping time
·If ControlLogix5563, cross loading time=(0.0013 ms * DINT)+1
Ms Housekeeping time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UFC718AE01, where DINT is the size of label data to be cross loaded, in 4-byte words.
Information to get Attribute data to get
type
explain
·Last cross loaded
size
·Last cross loaded
Dimensions (if slave
Frame)
LastDataTransfer
Size
DIN
T
This attribute gives the number of crossloads that have been or should be crossloaded in the last scan
According to size.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

·Dimensions are expressed in DINT (4-byte word).
·The controller must be configured as redundant.
·No slave racks are required.
Is there a synchronous slave rack for UFC718AE01?
·Yes – This attribute gives the number of DINTs that were cross loaded in the last scan.
·No – This attribute gives the DINT that should be cross loaded in the last scan
Number.
·Size of maximum cross loading
·Size of maximum cross loading
(If there is a slave rack)
MaxDataTransfer
Size
DIN
T
This property gives the maximum size of the LastDataTransfer Size property.
·Dimensions are expressed in DINT (4-byte word).
·The controller must be configured as redundant.
·No slave racks are required.
·To reset the value, use the SSV instruction with a source value of 0.
Is there a synchronous slave rack?
·Yes – This attribute gives the maximum number of DINTs to cross load.
·Yes – This attribute gives the maximum number of DINTs that should be cross loaded.

 

Packaging details: if you need an urgent delivery order, please feel free to contact us, and we will do our best to meet your needs.

Price problem: if you find that other suppliers offer cheaper prices for the same product, we are also willing to provide you with reference prices and give you further discounts.